Viewing inquiries for 05-1C1004

Submit new inquiry for this project


Inquiry #1: ITEM #75, MIDWEST GUARDRAIL SYSTEM, wood posts:
Typical Sections on Plan sheets 16 & 18, C-5 & C-7, Locations # 1 & 3, indicate that the distance from EP to HP varies from 2ft. to 4ft. Per RSP A77N3, if this distance is less than 4ft., it is a "Narrow Roadway Installation" situation, and 8" x 8" x 8'-0" posts with 8" x 8" x 1'-2" blocks must be used.
Please quantify the lengths of Typical and/or Narrow Roadway Installation.

Inquiry submitted 07/06/2017

Response #1:Submitted for consideration.
Response posted 07/06/2017


Response #2:Refer to Addendum No. 1, dated July 12, 2017. Plan Sheet C-5 design allows for 4' hinge.
Response posted 07/18/2017






The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.07, “JOB SITE AND DOCUMENT EXAMINATION” of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.