| CONTRACT NO: | 11-266104 |
| ROUTE / PM | 11-SD,Imp-8-R0.0/R10.0 |
| LOCATION | In San Diego And Imperial Counties From San Diego County Line To Route 98/8 Separation. |
| DESCRIPTION | Rubberized Hot And Warm Mix Asphalt Pavement Rehabilitation. |
| CONTRACT TYPE | A + B Bidding |
| ESTIMATE | $11,900,000 |
| WORKING
DAYS |
260 |
| ADVERTISE DATE | 09/26/2011 |
| BID OPENING | 11/10/2011 |
| LAST
POSTING |
11/09/2011@ 15:00
|
The Caltrans District
11 Office is located at 4050 Taylor Street, San Diego, CA 92110. The
District 11 Duty Senior telephone number is (619) 688-6635. Please
submit all inquiries in the proper format by fax to (619) 688-6988 or
e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to
bidder' inquiries, unless incorporated into a formal addenda to the
contract, are not a part of the contract and are provided for the
bidder's convenience only. In some instances, the question and answer
may represent a summary of the matters discussed rather than a
word-for-word recitation. The responses may be considered along with
all other information furnished to prospective bidders for the purpose
of bidding on the project. The availability or use of information
provided in the responses to bidder' inquiries is not to be construed
in any way as a waiver of the provisions of Section 2-1.03 of the
Standard Specifications or any other provision of the contract, the
plans, Standard Specifications or Special Provisions, nor to excuse the
contractor from full compliance with those contract requirements.
Bidders are cautioned that subsequent responses or contract addenda may
affect or vary a response previously given.
Caltrans District 11 Construction
Department has developed this method of answering Bidder's Inquiries to
better serve the needs of the Contractors who bid on our Projects.
Caltrans District 11 Construction Department will post all of the
questions submitted by any of the contractors that are registered
Planholders for that Contract, but reserves the right to not answer any
questions deemed unsatisfactory for public viewing.
The BIDDER'S
INQUIRIES & RESPONSES will be updated continuously and all attempts
will be made to do the final posting by 15:00 on the day prior to the
bid opening.
INFORMATION
AVAILABLE
|
|
|
|
|
|
|
|
|
ORDERING PROJECT PLANS AND SPECIFICATIONS
5% UDBE Requirement * Cost per set: Bidders:
$E-ad, Non-bidders: $E-ad
ADDENDUM
|
|
BIDDER'S INQUIRY SUBMITTAL FORM
|
|
Inquiry |
|
1 Q:09/27/11 |
Plan Sheet / Specification Reference= Special Provision Section 10-1.19: Cold Plane Asphalt Concrete Pavement (Page 68) Question= This specification indicates that the contractor shall schedule cold planing activities to ensure hot mix asphalt (HMA) is placed over cold planer area during the same shift before opening to traffic. The process as decribed in the plans is to cold plane, install asphalt-rubber seal coat and then overlay with either RHMA-G or RWMA-G. There is no (HMA) that is placed after cold planing. Will this specification apply to this project? Will Caltrans require all operations described above to occur within the same traffic window prior to opening to traffic or can the contractor cold plane and cover with asphalt-rubber seal coat prior to opening to traffic and install the RHMA or RWMA at a different time in the project? This has a large impact on the durtion of days bid by the contractor.
|
|
2 Q:10/05/11 |
Plan Sheet / Specification Reference= The 'Special Notices' for this project state 'work includes producing and placing rubberized hot mix asphalt (gap graded) and constructing on control section of RHMA-G and four test sections of RHMA-G mixed with different warm mix asphalt additives'. Question= If this project has been developed to evaluate warm mix asphalt why are only 'approved' products being specified? Will the foaming plants (Astec and Gencor) be permitted on this project? This would be a great opportunity to evaluate and test this technology.
|
|
3 Q:10/05/11 |
Plan Sheet / Specification
Reference= Section 10-1.22 Construction - RHMA-G with WMA additive
production and placement: Question= This section states 'produce an asphalt mixture within the temperature range of 220 degrees F and 240 degrees F'. How will this be accomplished when the RHMA-G requirements for the mixing temperature of the asphalt rubber binder must be between 375 degrees F and 425 degrees F and the compaction temperature of the combined mixture must be between 290 degrees F and 300 degrees F? In addition, temperature for the testing the viscosity of the rubber blended oil is 375 degrees F. How is the supplier to lower the temperatures of the WMA to 220 and 240 degrees F with these requirements? Will there be an amendment to the specifications addressing these requirements?
|
|
4 Q:10/06/11 |
Plan Sheet / Specification
Reference= Section 10-1.22 Construction - RHMA-G with WMA additive
production and placement Question= 1. Specification does indicate what will the lay down temperature range be for the WMAR. Will the lay down temperature range be provided? Will the laydown temperature range change to WMA process/additive?
2. How do you have a "Pilot" project with firm specifications? Isn't the idea to see if it works with higher and lower temps and to experiment to some degree under the State's direction?
|
|
5 Q:10/12/11 |
Plan Sheet / Specification Reference= 20-ASPHALT RUBBER BINDER Question= Since
Warm Mix Asphalt Rubber is being used for the Hot Mix, would Caltrans
entertain the idea of using Warm Mix in the Asphalt Rubber for the chip
seal portion of work?
|
| 6 Q:10/28/11 R: 10/28/11 |
Plan Sheet / Specification Reference= 10-1.22 Rubberized Hot Mix Asphalt (Gap Graded) With Warm Mix Asphalt Technologies, 10-1.23 Rubberized Hot Mix Asphalt (Gap Graded), and 39-1.03 Hot Mix Asphalt Mix Design Requirements Question= Is
the intent to perform a unique mix design and JMF verification for each
of the four WMA technologies and the RHMA for a total of five mix
designs and five JMF verifications?
|
| 7 Q:10/28/11 R: 11/04/11 |
Plan Sheet / Specification Reference= 10-1.22 Rubberized Hot Mix Asphalt (Gap Graded) With Warm Mix Asphalt Technologies, 10-1.23 Rubberized Hot Mix Asphalt (Gap Graded), and 39-1.03 Hot Mix Asphalt Mix Design Requirements Question= The final draft Caltrans WMA specification
includes the following, “Prepare samples in accordance with California
Test 304. Cure samples in a forced air draft oven at 275 °F for 4
hours +/- 10 minutes.” Should this be included in sample
preparation for this project?
|
| 8 Q:10/28/11 R: 10/31/11 |
Plan Sheet / Specification Reference= 15 Remove Asphalt Concrete Dike, 28 Place Hot Mix Asphalt Dike Question= In areas where existing asphalt concrete
dike abuts rock, is the state willing to leave the dike in place?
|
| 9 Q:10/31/11 R: 10/31/11 R: 11/04/11 |
Plan Sheet / Specification Reference= Pages 55-57 of the Special Provisions. Question= The traffic charts on Pages 55-57 of the
Special Provisions indicate that all freeway lanes and ramps must be
open during certain portions of the mornings and evenings. Due to the
remote job location and nature of the work, would the State allow 24
hour lane/ramp closures?
|
| 10 Q:11/01/11 R: 11/09/11 |
Plan Sheet / Specification Reference= 6-1.085 Buy America. Question= Since this project is subject to Buy
America requirements, will aggregate produced in and imported from
Mexico be allowed to be incorporated within the project or will the
only allowable aggregate be that which is produced in the United States?
|
| 11 Q:11/01/11 R: 11/03/11 |
Plan Sheet / Specification Reference= Item #38- Chain Link Fence (TypeCL-4, Vinyl-Clad)4720 LF Question= (1)Construction Details Sheet C-5 shows a
detail of Chain Link Fence with 2 truss rods in between the posts.
Posts are noted to be 8' apart maximum with a 2 3/8" Schedule 40 pipe
sleeve in the post footing. The question is: will this 8' fence section
be representative of the entire fence line or is it only in certain
sections of the fence?
(2)Would it be possible to
get some sort of layout for the fence?
|
| 12 Q:11/01/11 R: 11/03/11 |
Plan Sheet / Specification Reference= 39-1.03E Question= Specifications Section 39-1.03E states that the Engineer verifies the JMF from samples take from HMA produced by the plant to be used. Please verify that
|
| 13 Q:11/02/11 R: 11/03/11 |
Plan Sheet / Specification Reference= Item 28 Place Hot Mix Asphalt Dike, Sheet 26 Question=Where new AC Dike is to be installed-Will shoulder backing be required? if so, how will this work be paid?
|
| 14 Q:11/04/11 R: 11/04/11 |
Plan Sheet / Specification Reference= Question= Will the contractor be required to verify the JMF five times including four times with the warm mix additives?
|