| CONTRACT NO: | 11-259804 |
| ROUTE / PM | 11-SD-78-15.3/15.7 |
| LOCATION | In San Diego County In Escondido And San Marcos From 0.2 Mile West To 0.2 Mile East Of Nordahl Road Overcrossing. |
| DESCRIPTION | Replace Nordahl Bridge And Widen Off-ramp. |
| CONTRACT TYPE | A + B Bidding |
| ESTIMATE | $10,000,000 |
| WORKING
DAYS |
630 |
| ADVERTISE DATE | 09/12/2011 |
| BID OPENING | 11/03/2011 |
| FINAL POSTING |
11/03/2011@
06:55
|
The Caltrans District
11 Office is located at 4050 Taylor Street, San Diego, CA 92110. The
District 11 Duty Senior telephone number is (619) 688-6635. Please
submit all inquiries in the proper format by fax to (619) 688-6988 or
e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to
bidder' inquiries, unless incorporated into a formal addenda to the
contract, are not a part of the contract and are provided for the
bidder's convenience only. In some instances, the question and answer
may represent a summary of the matters discussed rather than a
word-for-word recitation. The responses may be considered along with
all other information furnished to prospective bidders for the purpose
of bidding on the project. The availability or use of information
provided in the responses to bidder' inquiries is not to be construed
in any way as a waiver of the provisions of Section 2-1.03 of the
Standard Specifications or any other provision of the contract, the
plans, Standard Specifications or Special Provisions, nor to excuse the
contractor from full compliance with those contract requirements.
Bidders are cautioned that subsequent responses or contract addenda may
affect or vary a response previously given.
Caltrans District 11 Construction
Department has developed this method of answering Bidder's Inquiries to
better serve the needs of the Contractors who bid on our Projects.
Caltrans District 11 Construction Department will post all of the
questions submitted by any of the contractors that are registered
Planholders for that Contract, but reserves the right to not answer any
questions deemed unsatisfactory for public viewing.
The BIDDER'S
INQUIRIES & RESPONSES will be updated continuously and all attempts
will be made to do the final posting by 15:00 on the day prior to the
bid opening.
INFORMATION
AVAILABLE
|
|
|
|
|
|
|
|
ORDERING
PROJECT PLANS AND SPECIFICATIONS
ADDENDUM
|
|
BIDDER'S INQUIRY SUBMITTAL FORM
|
|
Inquiry |
|
1 Q:09/12/11 |
Plan Sheet / Specification Reference= Bid item #94, sheet No. 289: Precast prestressed concrete girder Question= Sheet No. 289 shows precast girder depth as 4'-5". Caltrans standard bulb-tee girder section nearest to this size is 4'-7" deep (1400mm). Please confirm that 4'-7" deep BT girder is acceptable.
|
|
2 Q:09/30/11 |
Plan Sheet / Specification Reference= Item # 94, Precast prestressed concrete bulb-tee girders. Plan sheet # 289. Question= Regarding the response to question #1: With respect, if the Engineer wishes to deviate from a Caltrans standard girder size by 2", then please consider making the depth reduction in the top and/or bottom flange thickness, instead of the web. Precasters in this state have invested in steel forms for the manufacture of Caltrans bulb-tee girders. You cannot take 2" out of the web of a steel form. A completely new steel form will be needed for a 4'-5" deep girder, adding tens of thousands of dollars (public money) to the cost of this job. A budget-conscious state government should seriously consider the cost-effectiveness of design decisions. Can you please either reduce the flange thicknesses by 2", while keeping the girder depth at 4'-5", or allow the girder to be 4'-7" deep.
|
|
3 Q:09/30/11 |
Plan Sheet / Specification Reference= Sheet 73 & 74. Joint Overhead Utility. Question= Regarding the location of the Joint Overhead Utility (SDGE 12kv and Fiber Optics) to the east of the bridge, is there a plan to de-energize this line for any period during construction? The current location would severely hampers several operations.
|
|
4 Q:10/25/11 |
Plan Sheet / Specification Reference= Item 76 Asphalt Emulsion (Fog Seal Coat), plan sheets 2 and 153 Question= Plan Sheet 2, Note 5
states Fog Seal must be applied to all HMA surfaces EXCEPT traveled
ways and detours.
|
|
5 Q:11/02/11 |
Plan Sheet / Specification Reference= Item 147 Concrete Barrier Type 60 Question= Ref. Plan Sheet 44 of 306- Concrete Barrier Type 60C ENRA Line Table.- Sta 851+25 to 851+75 have data that will result in total barrier height less than the minimum 36" called for by Standard plan A 76 series, and are in fact less than the 32" shown for Type 60S on Std Plan A 76 H. Will this be corrected before the bid or after via CCO.
|