BIDDER'S INQUIRIES & RESPONSES
DISTRICT 11 CONSTRUCTION

CONTRACT NO: 11-2T0404 Recovery Act Funded
ROUTE / KP 11-SD-5, 805-R49.9/R51.7, 42.6/46.5
LOCATION In San Diego County In San Diego On Route 805 From 0.3 Km South Of Soledad Canyon Bridge And Overhead To 0.6 Km North Of Route 5/805 Separation And On Route 5 From 0.6 Km North Of Route 5/805 Separation To 0.5 Km North Of Carmel Mountain Road Undercrossing.
DESCRIPTION Construct Hov Lanes And Direct Access Ramp.
CONTRACT TYPE A + B Bidding
ESTIMATE $49,000,000
WORKING DAYS
890
ADVERTISE DATE 11/08/2010
BID OPENING 12/16/2010
FINAL POSTING
12/15/2010 @ 14:00

Bid Summary

The Caltrans District 11 Office is located at 4050 Taylor Street, San Diego, CA 92110. The District 11 Duty Senior telephone number is (619) 688-6635. Please submit all inquiries in the proper format by fax to (619) 688-6988 or e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to bidder' inquiries, unless incorporated into a formal addenda to the contract, are not a part of the contract and are provided for the bidder's convenience only. In some instances, the question and answer may represent a summary of the matters discussed rather than a word-for-word recitation. The responses may be considered along with all other information furnished to prospective bidders for the purpose of bidding on the project. The availability or use of information provided in the responses to bidder' inquiries is not to be construed in any way as a waiver of the provisions of Section 2-1.03 of the Standard Specifications or any other provision of the contract, the plans, Standard Specifications or Special Provisions, nor to excuse the contractor from full compliance with those contract requirements. Bidders are cautioned that subsequent responses or contract addenda may affect or vary a response previously given.
Caltrans District 11 Construction Department has developed this method of answering Bidder's Inquiries to better serve the needs of the Contractors who bid on our Projects. Caltrans District 11 Construction Department will post all of the questions submitted by any of the contractors that are registered Planholders for that Contract, but reserves the right to not answer any questions deemed unsatisfactory for public viewing.
The BIDDER'S INQUIRIES & RESPONSES will be updated continuously and all attempts will be made to do the final posting by 15:00 on the day prior to the bid opening.


INFORMATION AVAILABLE



BID ITEMS
 SPECIALS
PLANS
 PLANHOLDERS
INFORMATION HANDOUT

X-SECTIONS



ORDERING PROJECT PLANS AND SPECIFICATIONS   

5% UDBE Requirement * Cost per set: Bidders: $E-ad, Non-bidders: $E-ad



ADDENDUM



 

BIDDER'S INQUIRY SUBMITTAL FORM


Inquiry No.
Inquiry

   1

  Q:11/19/10
R:11/30/10

R:12/06/10

Plan Sheet / Specification Reference= Item 55-66, Earthwork, Plan Sheet Q-7, Special Provisions Section 10-1.36


Question= Plan Sheet Q-7 Summary of Quantities denotes two areas as **FOR BALANCING THE EARTHWORK WITH IN PROJECT LIMITS.
Special Provision Section 10-1.36 states that Surplus excavated material shall become the property of the Contractor and shall be disposed of in conformance with the provisions in Section 7-1.13, "Disposal of Material Outside the Highway Right of Way," of the Standard Specifications.

Please clarify if the intent is to accomodate all excess material from earthwork operations with in project limits as stated on sheet Q-7 leaving no net import or export. 

 

  • Your inquiry has been received and is being reviewed. Thank you for your patience
  • Yes. The intent is to accommodate all excess material from earthwork operations with in project limits as stated on sheet Q-7 leaving no net import or export even though the quantities of road excavation and embankments are slightly imbalanced leaving approximately 1900 Cubic Meters of excess material .

     

   2

  Q:11/19/10
R:11/30/10

R:12/06/10


Plan Sheet / Specification Reference= Special Provision Section 10-1.02 MATERIAL CONTAINING AERIALLY DEPOSITED LEAD


Question= Where on the plans is ADL is anticipated to be encountered? Where it is to be buried?
Please clarify the statement under Soil Handling stating...Surplus material excavated from areas containing aerially deposited lead shall remain in the area of soil disturbance. The surplus soil shall not be
disposed of outside the highway right of way.

Why is there not a bid item for handling ADL.

 

  • Your inquiry has been received and is being reviewed. Thank you for your patience
  • Per section 10-1.02, "Material Containing Aerially Deposited Lead," of the Special Provisions, Aerially deposited Lead will be encountered within 0.6 m of material in unpaved areas in the Highway Right of Way. This material shall not be disposed of outside the highway right of way and shall be disposed in areas where embankment is required. Compensation for handling Material Containing Aerially Deposited Lead shall be considered as included in the various items of work.

   3

  Q:11/22/10
R:11/30/10

R:12/06/10


Plan Sheet / Specification Reference= Bid Item# 85- Water Meter 3 Each. Special Provision Section 10-2.05 Water Meter


Question= The Specail provisions states a specified sum for 2 each water meters and the bid item indicates 3 each.  Please clarify if there is 2 or 3 meters and the total to be included for such meters.

 

  • Your inquiry has been received and is being reviewed. Thank you for your patience
  • The Bid Item List in the Bid Book (or the Copy of Bid Item List in the special provisions) is correct and Plan Sheet IP 1 shows 2 - 50 mm water meters and IP 2 shows 1 - 40 mm water meter.
     

  4

  Q:12/07/10
R:12/08/10


Plan Sheet / Specification Reference= 106, Steel Casing


Question= Can corrugated metal pipe be used for Steel Casing?

 

  • Reference Section 5-1.14 " Cost Reduction Incentive," of the Standard Specifications and the Amendments to the Standard Specifications. Proposals for modifications to the contract documents may be submitted to the Engineer after contract award.

  5

  Q:12/07/10
R:12/09/10


Plan Sheet / Specification Reference=# 132 Joint Seal Assembly (MR = 101-160 mm), # 133 Joint Seal Assembly (MR = 161-240 mm)


Question= Section 10-1.75 of the contract special provisions, Join Seal Assemblies (Movement Rating Exceeding 100 mm) states that “……cleaning and painting of all new metal surfaces of the joint seal assembly, except stainless steel and anchorages imbedded in concrete, may be substituted for galvanizing. Cleaning and painting shall be in conformance with the provisions in “Clean and Paint Joint Seal Assemblies” of the special provisions.” Section 10-1.90 of the contract special provisions, Clean and Paint Joint Seal Assemblies, references Section 59-3, “Painting Galvanized Surfaces” of the Standard Specifications. If a Joint Seal Assembly (Movement Rating Exceeding 100 mm) is galvanized, is it the intent of Section 10-1.90 that the surface also be painted and the requirements of Section 2-1.05 be submitted?

 

  • Reference Section 10-1.75, "Joint Seal Assemblies (Movement Rating Exceeding 100 mm)," of the special provisions.  Section 10-1.90, "Clean and Paint Joint Seal Assembly," of the special provisions only applies if cleaning and painting is substituted for galvanizing of joint seal assemblies (JSA's).  Proof of certification for painting JSA's, as required by Sections 10-1.90 and 2-1.05 of the special provisions is required if JSA's are painted.

  6

 Q:12/08/10
R:12/15/10

 


Plan Sheet / Specification Reference= Utiltiy Relocations Section 5-1.25 Utility Plan Sheet U-2


Question= Will the Utilties on MMBM Line between Stations 443+00 and 444+00 (I.e. Gas Line, Fiber Optic, TV, Electrical near RW443R) be removed or relocated with the Utility relocation work for the lines described as "Transverse BR Line"?

 

  • Yes, Work Windows are provided to allow for their relocation. They will be relocated by the Utility Company and/or their contractors.
 

  7

 Q:12/09/10
R:12/14/10

 

 Plan Sheet / Specification Reference=Utility work - Arranged time for Relocation Special Provisions 5-1.25, Page 37 Second Paragraph


Question= Can SDGE GAS and SDGE Electrical be scheduled for the same time
(at different locations) or ar they considered one Utility Owner?

  • For the purpose of scheduling, SDG&E underground utilities and SDG&E overhead utilities can be considered as separate owners.  Work by these two owners may be scheduled concurrently as long as the work is at two separate locations.

  8

 Q:12/10/10
R:12/15/10

 

Plan Sheet / Specification Reference= 66F - Geosynthetic Reinforced Embankment


Question= It is unclear if the facing units for the geosynthetic reinforced wall need to be fully enclosed gabion baskets or if they can be "L" shaped wire facing units (also refered to as baskets).  Gabions have 4 sides: front, back, top & bottom.  The "L" shaped wire units have two sides: a front and bottom.  It appears the "L" shaped units are acceptable, but clarification would be appreciated.

 

  • Please bid per the current contract documents.

  9

  Q:12/10/10
R:12/15/10


Plan Sheet / Specification Reference= Facing Detail, Sheet #875


Question= Typical height of the wall facing unit is 450mm. What is the typical width of the wall facing unit?

 

  • Please bid per the current contract documents.

  10

  Q:12/10/10
R:12/15/10


Plan Sheet / Specification Reference= Facing detail note #3, Sheet 875.


Question= Are stainless steel hog rings an acceptable corrosion resistance connection?

  • Please bid per the current contract documents.

  11

  Q:12/10/10
R:12/15/10


Plan Sheet / Specification Reference= Facing Detail, sheet 875


Question= Is the Stone Face Fill supposed to be completely encased in Wire Facing or is the Wire Facing only on the outer face and bottom of the Stone Face Fill?

  • Please bid per the current contract documents.
   

 