BIDDER'S INQUIRIES & RESPONSES
DISTRICT 11 CONSTRUCTION
CONTRACT NO:  11-080924
ROUTE / KP 11-SD-15-M38.7/M42.7 
LOCATION In San Diego County In San Diego From 0.5 Km North Of Rancho Bernardo Road Undercrossing To 0.7 Km South Of Via Rancho Parkway Overcrossing.
DESCRIPTION Construct Additional Lanes, Movable Barriers, And Replace Bridges.
ESTIMATE $ 88,000,000.00
DESIGN SEQUENCING PROJECT
ADVERTISE DATE 05/17/04
BID OPENING 07/15/04  08/05/04
LAST POSTING 08/04/04    @  17:15

BID RESULTS
  1 
FCI CONSTRUCTORS/BALFOUR BEATTY, A JOINT VENTURE $ 81,952,560.00
2
YEAGER SKANSKA INC. $ 86,474,702.00
3
MCM CONSTRUCTION INC. $ 91,604,414.60
4
CSI AND CCMA A JOINT VENTURE $ 93,424,999.50

The Caltrans District 11 Office is located at 2829 Juan Street, San Diego, CA 92110. The mailing address is P.O. Box 85406, San Diego, CA 92186-5406. The District 11 Duty Senior telephone number is (619) 688-6635. Please submit all inquiries in the proper format by fax to (619) 688-6988 or e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to bidder' inquiries, unless incorporated into a formal addenda to the contract, are not a part of the contract and are provided for the bidder's convenience only. In some instances, the question and answer may represent a summary of the matters discussed rather than a word-for-word recitation. The responses may be considered along with all other information furnished to prospective bidders for the purpose of bidding on the project. The availability or use of information provided in the responses to bidder' inquiries is not to be construed in any way as a waiver of the provisions of Section 2-1.03 of the Standard Specifications or any other provision of the contract, the plans, Standard Specifications or Special Provisions, nor to excuse the contractor from full compliance with those contract requirements. Bidders are cautioned that subsequent responses or contract addenda may affect or vary a response previously given.
Caltrans District 11 Construction Department has developed this method of answering Bidder's Inquiries to better serve the needs of the Contractors who bid on our Projects. Caltrans District 11 Construction Department will post all of the questions submitted by any of the contractors that are registered Planholders for that Contract, but reserves the right to not answer any questions deemed unsatisfactory for public viewing.
The BIDDER'S INQUIRIES & RESPONSES will be updated continuously and all attempts will be made to do the final posting by 15:00 on Wednesday prior to the bid opening.
INFORMATION AVAILABLE
 FACT SHEET
 BID ITEMS
 SPECIALS
 PLANS
 PLANHOLDERS
Interstate 15 Managed Lanes
 CROSS SECTIONS
           MIBs    
 
 
ADDENDUM

ADDENDUM NO.1 07/02/04
 ADDENDUM NO.2 07/21/04
 
 

BIDDER'S INQUIRY SUBMITTAL FORM
 

Inquiry No. Inquiry
1
Q:05/21/04
  R:06/05/04
Plan Sheet / Specification Reference=project Cross sections

We would like a electronic copy of the project cross sections.

  • Cross sections are available as of 06/05/04 and can be downloaded for printing from the link above at any local printing firm or on your own printing equipment:
         MESA BLUEPRINT
         5560 Ruffin Road Suite 5
         San Diego, CA 92123
         (858) 541-1500    FAX (858) 278-0558
         e-mail to  plot@mesablueprint.com San Diego, CA 92123
2
Q:05/26/04
 R:05/26/04
Plan Sheet / Specification Reference=Engineer estimate, bid item No. 63, 66, 69, 126, 137, 214 & 215

In the discription what does the symbol (R) stand for?
 

  • The letter (R) for the above contract items stands for Roadway.
3
Q:06/01/04
  R:06/07/04
Plan Sheet / Specification Reference=project Cross sections

We would like a set of cross-sections for project 11-080924.

  • See the response to inquiry No. 1.
4
Q:06/08/04
 R:07/02/04
Plan Sheet / Specification Reference=Item # 196, Concrete Barrier (Type 26 Mod), Item # 217 Concrete Barrier (Type KA-26), Item # 117, Structural Concrete Brigde: Special provisions, section 10-1.64 Arq Surface (Textured Conc)(Page 265; SP Section 10-1.92, Concrete Barrier.

SP, section 10-1.64 Arq Surface (Textured Conc)(Page 265) say that
architectural treatment on pilasters and sconces shall be paid under structural concrete, bridge.  On the other hand, SP, section 10-1.92, Concrete Barrier, say that concrete for the sconces and their arquitectural texture shall be paid under the various types of concrete barrier involved.  Under what contract item should concrete and arquitectural texture forsconces and pilasters be paid?
 

  • Please refer to Addendum No. 1.
 
5
Q:06/11/04
  R:06/17/04
Plan Sheet / Specification Reference=

We are asking for a postponement of the bid date for a minimum of one month. With the addendums and postponement of Contract 11-080914, we have been unable to start work on this project. Also, the NCTD San Marcos Loop segment
is scheduled for release in two weeks.

  • There will be no delay.  Bid opening will take place as scheduled. 
6
Q:06/15/04
  R:07/02/04
Plan Sheet / Specification Reference=Item #36 Remove Yellow Painted Traffic Stripe, M, 2160, SHT. TH-5 STAGE I, Specials pg. 197.

The area where indicated by station that (leaded) yellow stripe-exists may have been repaved and repainted within the last 3-4 years, with non-leaded paint.  At least 90% of the N/B was repainted in the past year.  Please check and adjust Item #36 accordingly.
 

  • Please bid per the contract documents.
 
7
Q:06/17/04
  R:07/16/04
  R:07/23/04
Plan Sheet / Specification Reference=105 to 113 and 115.

When will Geotechnical Design Reports be made available?  Where and when will we be able to view the cores?
 

  • Please refer to Addendum No. 2. Please contact Shawn Wei at 916-227-5252 for Highland and Duenda bridges and Mark Desalvatore at 916-227-5391 for Lake Hodges and Green Vly Creek bridges. 
 
8
Q:06/17/04
  R:07/02/04
Plan Sheet / Specification Reference=.

Do to the delays in the previous contracts along this corridor and other large contracts bidding (Bolsa Chica Lowlands Restoration Porject)around the same time we would request a one to two month psotpnement of the bid date.
 

  • Please refer to Addendum No. 1.
 
9
Q:06/21/04
  R:07/06/04
Plan Sheet / Specification Reference=#1)Item #57) Roadway Excavation #2)Pg. #75 & #77 of the special provisions: Prequalification Questionnaire.

#1)There are no natural ground contours on the layout or contour grading plans within the project right of way. When will the plans be revised to show these?
 

  • Please refer to the CROSS SECTIONS link.


#2) Shouldn't we prequalify before the bid and not after? Maybe this should be called a post qualification questionnaire. 
 

  • Please bid per the contract documents.
 
10
Q:06/21/04
  R:07/23/04
Plan Sheet / Specification Reference=111 and 113, Install Permanent Steel Casing, Section 8-1.03 State-Furnished Materials.

Could you provide details on the State-Furnished Casing, such as;individual lengths, splicing requirements, thicknesses, method of construction (spiral or plate), driving shoes, thickened sections, picking attachments, and weights?
 

  • Please refer to Addendum No. 2.
 
11
Q:06/21/04
  R:07/02/04
Plan Sheet / Specification Reference=

DUE TO A HEAVY BID SCHEDULE, WE ARE REQUESTING THAT THE BID DATE BE POSTPONED BY 4 WEEKS.
 

  • Please refer to Addendum No. 1.
 
12
Q:06/23/04
  R:07/02/04
Plan Sheet / Specification Reference=Item #90 Water Meter, Sheet 322, SP
10-2.04 Water Meter 

Question=Does the City of San Diego established fee of $19,052 include all
costs associated with construction of a new wet tap water service, meter,
permanent surface restoration. If not what does the city fee specifically
include?
 

  • The fee associated with the water meter should cover all costs for the water meter installation, wet tap and service lateral that extends from the water main.  The fee also includes a water capacity charge and all taxes.
 
13
Q:06/23/04
 R:07/23/04
Plan Sheet / Specification Reference=#163 300mm DIP, #167 300mm WSP, Sheet
324/325/326 SP 10-4.18 Hi-Line

Question=Is a temporary hi-line required after the city performs the cut and
plugs at both the Highland and Duenda bridge locations, and the existing
300mm water line is taken out of service at these two specific locations? If
so does the city perform this work for a fee (what is the fee amount), or
does the contractor perform the work?
 

  • No temporary hi-line is required. All connections to existing water mains are to be done by the City.  Fee for cut and plug is $6,248.00, and fee for reconnect is $5,579.00 (SSP 10-4 connections to water mains).
14
Q:06/23/04
 R:07/23/04
Plan Sheet / Specification Reference=Special provisions section 5-1.19 Sound
Control

Question=This section states that if birds are decected in adjacent habitat
the construction noise levels shall be decreased to 60 dbA, or the activity
shall be ceased.  If the activities are ceased, will this be considered a
right of way delay?
 

  • No.
 
15
Q:06/25/04
  R:07/02/04
Plan Sheet / Specification Reference=Sign Plan Sheets and Lighting & Sign Illumination

Question=There are no details shown on the Sign Plan Sheets S1-S15 (452-466).  Where and what sign go where?  There are also no Roadside Sign Quantities shown S17-S20.  What are these quantities and where are they located? 
There are no details shown for the Lighting and Sign Illumination and Fiber Optic Communication System Plan Sheets E1-E16.  Please provide drawings that show where the electrical systems are going? 
 

  • Please refer to Addendum No. 1.
 
16
Q:06/25/04
 R:07/02/04
Plan Sheet / Specification Reference=Postponement

Question=We are requesting a postponement due to the delay in submission of contract bid # 11-080914.
 

  • Please refer to Addendum No. 1.
 
17
Q:06/28/04
 R:07/02/04
Plan Sheet / Specification Reference=Roadway Excavation

Question=Will the state provide boarings for the native cut areas on this
contract and if not will the State allow the contract to explore the these
cut areas.
 

  • No. The State does not provide any borings for the cut slope areas on this contract. The contractors are allowed to explore the cut slopes on their own, through obtaining an encroachment permit. 
 
18
Q:06/28/04
  R:07/02/04
Plan Sheet / Specification Reference=RW 431

Question=RW 431R is shown on the layout sheets but there are no details or
quantities for this wall.  Does it exist, and if so, when will the design
sheets be sent out.
 

  • The details are available as part of the Structural Plans for the Lake Hodges bridge.
 
19
Q:06/28/04
  R:07/02/04
Plan Sheet / Specification Reference=

The Contract documents indicate that groundwater measurements were taken in some of the borings yet the LOTB's do not show a groundwater elevation.  Where can the groundwater elevation data be obtained?
 

  • The groundwater elevations are shown on the LOTBs, if encountered. 
20
Q:06/29/04
 R:07/08/04
 R:07/23/04
Plan Sheet / Specification Reference=

It is requested that Caltrans provide copies of any and all Geotechnical or subsurface investigation reports, tests, logs, etc, that pertain to the soils that will be encountered at the above referenced project and the bidders evaluation of drilling productions, rock compressive strength, tests performed on any rock cores, etc, to include the following:

1.      Materials information reports, sheets, handouts, or memos; 
2.      Foundation informational handouts, reports, sheets, memos; 
3.      Geotechnical design reports; 
3.      Geotechnical baseline reports. 
It is understood that the project plans contain boring logs, and that rock cores can be viewed in Sacramento.  It is our intent to view the written reports and any associated test results that were generated in conjunction with the boring logs and core samples.
 

  • Please refer to Bidder's Inquiry No. 7 and Addendum No. 2. 


 

21
Q:07/07/04
  R:07/20/04
Plan Sheet / Specification Reference=SP Sect 4

Question=In regards to design sequencing, is the 700 working days per the special provisions adequate for completion under normal working conditions?
 

  • Yes.
 
22
Q:07/07/04
  R:07/20/04
Plan Sheet / Specification Reference=Retaining Wall Drawings

Question=For RW's 435L, 435R, HV11L, and HV9L, there appears to be Buttress'; however, the spacing is not given.  What is the spacing?  Also, stations do not match with the lenghts of the Expansion Joints or the Lenght along LOL.  Please correct these. 
 

  • The information rquested is part of the phase III deliverables per Addendum No. 1. Please bid per the contract documents. 
23
Q:07/08/04
  R:07/20/04
Plan Sheet / Specification Reference=ITEM # 198, CONCRETE BARRIER TYPE A, 

Question=PLAN SHEET # 476, RETAINING WALL 413M, AND PLAN SHEET # 477,
RETAINING WALL 416M DO NOT SHOW A CONCTRETE BARRIER TYPE "A", HOWEVER ON PLAN SHEET # 492M,RETAINING WALL QUANTITIES, THERE ARE QUANTITY VALUES FOR TYPE "A" BARRIER ON THESE TWO WALLS.  IS THERE CONCRETE BARRIER TYPE "A" ON RETAINING WALLS 413M AND 416M?
 

  • The retainin wall quantity sheet for retaining walls 413M and 416 M are correct.
 
24
Q:07/08/04
 R:07/23/04
Plan Sheet / Specification Reference= ITEM # 127, TILE TEXTURE PATTERN BULL
NOSE,

Question=WHERE IS THIS FOUND IN THE SPECIAL PROVISION SECTION
 

  • Please refer to Section 10-1.64 ARCHITECTURAL SURFACE (TEXTURED CONCRETE) and Section 10-1.92 CONCRTE BARRIER of the Special Provisions. 
25
Q:07/12/04
  R:07/20/04
Plan Sheet / Specification Reference=Item # 127, and Pilaster Details

Question=How do you quantify the Tile-Texture Pattern Bull-Nose item.  There are no details of how you measure it to come up with a M3 quantity.  What are the details for pilasters on the Retaining Walls?
 

  • Please refer to Addendum No. 1  for the Tile-Texture Pattern Bull-Nose item. The details for pilasters on the retaining walls  is part of the phase III deliverables per Addendum No. 1. Please bid per the contract documents. 
 
26
Q:07/13/04
  R:07/23/04
Plan Sheet / Specification Reference=Addendum #1, Page 4, deletes Section 10-1.41 Decomposed Granite and Section 10-1.47 Rock mulch from the Special Provisions. On the engineer's estimate there remains however, bid items #72 Rock Mulch & #73 Decomposed Granite.

Question=Will these items subsequently be deleted from bid schedule or how are we to deal with them ?
 

  • Please refer to Addendum No. 2.
 
27
Q:07/13/04
  R:07/16/04
Plan Sheet / Specification Reference=

Will the cores be made available for viewing as stated on the boring logs?

  • Please refer to the response to bidder Inquiry No. 7.
28
Q:07/14/04
  R:07/20/04
Plan Sheet / Specification Reference=

Retaining Walls 413M, 416M have buttresses as shown on Plan Sheets 476-477.  However, Plan Sheets 488-489 do not qualify which buttress detail should be used at these two walls.  Please Clarify. 
 

  • The information rquested is part of the phase III deliverables per Addendum No. 1. Please bid per the contract documents. 
 
29
Q:07/15/04
  R:07/20/04
Plan Sheet / Specification Reference=

Please see Plan Sheet 478.  The RW footing for wall expansion joint sections 6 & 7, gives a TOF=122.150.  The RW footing for wall expansions joint section 8 gives a TOF=122.301 however, this footing for wall section 8 is graphically depicted “lower” than the footing for wall sections 6 & 7.  Please clarify.
 

  • The information rquested is part of the phase III deliverables per Addendum No. 1. Please bid per the contract documents. 
30
Q:07/15/04
  R:07/20/04
Plan Sheet / Specification Reference=

Where is the “pilaster” detail called out on Plan Sheets 476, 482, and 483.  Sheet 476 states “See Retaining Wall Details.”  Retaining Wall “Detail Sheets” R15-R20 do not appear to have a “pilaster” detail.  Please clarify.
 

  • The information rquested is part of the phase III deliverables per Addendum No. 1. Please bid per the contract documents. 
 
31
Q:07/15/04
  R:07/23/04
Plan Sheet / Specification Reference=

Will Caltrans consider a steel escalation clause in an addendum? 
Specifically, because the steel industry is so volatile at this time, the price for permanent steel casing cannot be guaranteed from the time of bid to the time of purchase.  A steel escalation clause will allow all bidders to work on a level playing field without undue contingency fees for steel escalation.
 

  • No. 
32
Q:07/16/04
  R:07/23/04
Plan Sheet / Specification Reference=Bid Items 110 & 112 Permanent Steel
Casings. Plan sheets 712, 776, and 754 

Question=Plan Sheets # 712, 776, and 754 show cross-sectional details for
2.6m Steel Casing and 1.4m Steel Casing, respectively. None of the
cross-sections show the minimum wall thickness for these Steel Casings.
Please provide minimum wall thickness for both 2.6m and 1.4m Steel Casings.

  • No minimum wall thickness requirements are set for these items.
 
33
Q:07/16/04
  R:07/20/04
  R:07/23/04
Plan Sheet / Specification Reference=

Question=(1) For the Green Valley Creek Bridge, will a construction joint be allowed below pile cutoff at the bottom of the column cage?

  • This is a Design Sequencing Project. Please refer to Section 1, "Specifications and Plans" of the special provisions, paragraphs 6 and 7.
(2) Design memorandums for CIDH piles require a minimum of 5" X 5" windows for concrete flow. This appears to be in conflict with section 10-1.55 of the special provisions, which calls for 75mm clear space between PVC test pipes and vertical reinforcing. Please clarify which requirement shall supercede. 
  • Design memorandums are not part of the contract documents. The special provisions are the contract requirements.


(3) To avoid steel escalation, if all of the permanent steel casing for the CIDH piles is purchased during the first phase of construction, will it be paid upon delivery to the site? Is there a location to have it stored on site?
 

  • Payment upon delivery of this material is covered under Section 5-1.16 "Payments," of the special provisions for materials furnished but not incorporated in the work. Payment for the material purchased would be made in accordance to section 9-1.06 "Partial Payments" of the Standard Specifications. Staging areas shown on the plans and any other other locations within the project limits may be used if approved by the Resident Engineer. 


(4) Section 10-1.55 "Piling," of the Special Provisions indicates  that "Acceptance tests of the concrete will be made by the Engineer..." and "Tests will included gamma-gamma logging."  Pursuant to section 6-3.01 of the Standard Specifications, "...all tests shall be performed in accordance with the methods used by the Department of Transportation...", however we are unable to locate Caltrans' defined test method for gamma-gamma logging.  Accordingly, please provide the following information:

 Defined procedures for gamma-gamma logging (Cal Test number);
 Defined procedures for interpretation of gamma-gamma logging results;
 Defined procedures for re-test and interpretation of gamma-gamma logging.
 

  • To date Caltrans has not yet completed the writing of a test method.  For information regarding this type of foundation testing you can visit the following website:http://www.dot.ca.gov/hq/esc/geotech/ft/gamma.htm


(5) What are the dimensions of the State furnished casing for CIDH Piles?
 

  • Please refer to Addendum No. 2.
 
34
Q:07/16/04
  R:08/03/04
Plan Sheet / Specification Reference=

Please see Plan Sheets 760 and 761.  Note 1 indicates details not shown are found on the “Retaining Wall Details No.2 Sheet.”  The referred to sheet does not give the footing thickness for the retaining walls.  Scaling the dimensions gives 550mm.  Is this correct.  Please clarify. 

  • Sheet 768, Retaining Wall Details No. 2, indicates that for details not shown, see Revised Standard Plan B3-1.  This standard plan provides details for the retaining walls including footing dimensions. 
35
Q:07/17/04
  R:07/23/04
Plan Sheet / Specification Reference=Item #'s 174-177, 181 Sht #295, 317,
448, SP 10-1.80 

Question=The drainage quantity sheets lists several drainage systems as
having RSP. However, it is only reflected on the drawings on two systems
(25a and 36a). Also, a seperate quantity sheet (448) lists RSP quantities at
the abutments on the Lake Hodges bridge, but no details are given on the
bridge plans or elseware. Please provide locations and details for RSP
quantities.
 

  • Details will be provided as part of the phase II deliverable. Please see Addendum No. 1.
 
36
Q:07/19/04
 R:07/29/04
Plan Sheet / Specification Reference=Plan sheets SC-1 thru SC-12.

Question=Stage 1A calls for a temporary AC widening for NB 15.  However,
there is no typical section, structural section or quantities for this work.
In addition, the k-rail in this stage does not protect this work area from
NB 15.  How does Caltrans intend to do this work and pay for it? 
 

  • The temporary AC widening will be handled in accordance with section 4-1.03 CHANGES of the Standard Specifications.  The K-rail shown is not meant to protect this construction work area from traffic. It will temporarily act as a positive barrier in lieu of the removed Thrie Beam guard rail. 
37
Q:07/26/04
 R:07/30/04
Plan Sheet / Specification Reference=Materials Information Handout- Lake Hodges Operating Levels.

Question=It is unclear as to what operating level of Lake Hodges will be
maintained from current time thru September 2006.  Is it correct to assume
that elevation 290' MSL will be maintained during this time?
 

  • No.  The operating level of Lake Hodges varies with weather and surface water

  • inflow.  From the current time until approximately January 2006, Lake Hodges
    will be controlled by weather and surface water inflow.  From approximately
    January 2006 through September 2006 the operating level will be maintained
    at approximately elevation 290 or below for the construction of the Water
    Authority's Lake Hodges Projects.
38
Q:07/30/04
 R:08/03/04
Plan Sheet / Specification Reference=Item # 205 Crash Cushion (Quadguard).

 What model and type is requred?
 

  •  It is a QuadGuard Elite Model No. QS2411EY.
 
39
Q:07/30/04
 R:08/03/04
 R:08/04/04
Plan Sheet / Specification Reference=

Question=1)How will changes to final pay quatities (through the design sequencing process)be addressed after the bid? 
 

  • Please refer to section 9-1.015 FINAL PAY ITEMS of the Standard Specifications and the sections pertinant to the Final Pay Items in the Special Provisions of this contract.
2) Page 97 of the plans shows k-rail being staked to the top of ac dike. Is staking to take place only when k-rail sits on the ac dike, or for all k-rail?
 
  • Staking should be done for all k-rails of the Stage 1.
3)Is sand backfill of the existing pipe (N) no pay? The drainage quantities indicate on one schedule no pay and another that it will be payed.
 
  • Sand backfill is included in the price for abandon culvert. There is no item and a zero quantity for sand backfill. (N) Not a seperate pay item, for information only is inadverdently overlooked in the chart for sand backfill on page D-91 of DRAINAGE QUANTITIES. 
4) The as-built bridge plans cannot be obtained at the fax # shown on page 195 of the specifications. Where can we obtain these?
  • Plans of the existing bridges may be requested by fax from the Office of Structure Maintenance and Investigations, 1801 30th Street, Sacramento, CA, Fax (916) 227-8357, and are available at the Office of Structure Maintenance and Investigations, Norwalk, CA, Telephone (562) 868-3828.
5) In the materials information handout of addendum #2 for lake hodges operating levels:
   a) When will the project be completed?
  • The Water Authority's Lake Hodges Projects are currently scheduled to

  • be substantially complete by January 2008.
   b) The dates in item #1 (i.e. Sept 1 through Feb 28) what year is this for?
  • Please refer to the link for MIBs,  LAKE HODGES OPERATING LEVELS section.
   C) What have the current levels been for the last five years?
  • Please refer to the following link. The reservoir elevations are based on the 1929 datum. LakeHodges.pdf
6) It is our understanding that Cal Trans has been doing additional borings for this project. Will you make this information available to us prior to the bid?
  • There are no additional Borings available, post advertised date for this contract. 
40
Q:08/02/04
 R:08/03/04
Plan Sheet / Specification Reference=SC-49, Stage 2A, & Sheets 653-657 of 822.

Question=There is insufficent work area to construct the bents for Highland Bridge in stage 2A. How should we proceed?
 

  • The staging plans will be revised in accordance with Section 4-1.03 CHANGES of the Standard Specifications, in order to create an additional NB traffic shift at the end of Stage 1B.
 
41
Q:08/02/04
 R:08/03/04
Plan Sheet / Specification Reference=Item #63 & Item #66.

Question=Where are details for Structure Excavation (Retaining Wall) R & Structure Backfill (Retaining Wall) R to be found. Is the Backfill spec for R the same as for 95% or 90.

  • Please refer to section19-3.06 titled Structure Backfill of the Standard Specifications.
42
Q:08/02/04
 R:08/03/04
Plan Sheet / Specification Reference=Item 215 - Concrete Barrier (Type 736 Modified) (R); Plan Sheets 38, 39, 40, 484, and 485.

Question=Please provide details for this modified barrier. What are the
dimensions? Does it have a footing?

  • The details and dimensions for this Concrete Barrier (Type 736 Modified) ( R ) are similar to those shown in the Highland Road OC structural plans, on page 673 “Miscellaneous Details” and those shown on page 680, except for the tubular hand railing. 
43
Q:08/02/04
 R:08/03/04
Plan Sheet / Specification Reference=Item 197 - Concrete Barrier (Type 27B); Plan Sheet 487.

Question=Please provide details for this barrier rail.

  • A detail for the Concrete Barrier (Type 27B) is shown on Plan Sheet C-5, page 97.
 
44
Q:08/04/04
 R:08/04/04
Plan Sheet / Specification Reference=ITEMS 211, 212,213,- Previous Pre-Bid inquiry and Response #2; current plans, bid items; and Special provisions Section 10-1.92.

Question=1- The response to  previous pre-bid inquiry No. 2 states that the  "(R)" symbol for bid items 63,66,69.. etc. stands for Roadway. Please confirm that the (R) symbol for Items 211,212,213 also stands for Roadway.

  • Yes, the "(R)" symbol stands for Roadway for Items 211, 212, and 213.
2-Provide a detail for the 60 A (Roadway)barrier. Specifically what type of dowels shown on Std plan A76A are to be installed in the roadway paving structural section, since Std Plan A 76A requires dowels to " Bridge Deck".
  • Please bid per the contract documents.
3- Plan Sheet 110 shows a concrete barrier Type 60C R that is not addressed in Special provisions Section 10-1.92 or within the bid items. Confirm that this will be provided for in a later Phase of design for this project.
  • These details will be delivered in Phase III, per Addendum No. 1.
45
Q:08/04/04
 R:08/04/04
Plan Sheet / Specification Reference=Item Number127, 128, plan sheet 450, 492-493 

Question=What is the difference between item 127 TILE TEXTURE PATTERN BULL-NOSE, and item 128 ARCHITECTURAL SURFACE(BARRIER)?  The quantity summary for item 128 on sheet 450 covers walls 403M, 413M, 416M, and 423M.  Based upon the length of barrier on these walls the bid quantity covers approx. 340mm of rail height for the respective lengths of those walls.

According to the quantity summary on sheet 492-493 the quantity for item 127 covers those same four walls.  Based upon the revised bid quantity of 2500 M2,
this covers an average of 860mm of rail height for those walls.

Finally, walls HV11L and HV9L also show barrier rail with tile texture but according to the summaries neither bid item appears to address these two walls.

Which item should cover payment for the tile texture on the barrier rail for the six walls in question?

Please advise.

  • The difference between the contract items 127 and 128 is mainly in the height and radius size. Plerase refer to section 5-1.04 COORDINATION AND INTERPRETATION OF, PLANS STANDARD SPECIFICATIONS, AND SPECIAL PROVISIONS FOR THE REMAINDER. 
46
Q:08/04/04
 R:08/04/04
Plan Sheet / Specification Reference=Item Number 210 CONCRETE BARRIER (TYPE 80)

Question=The quantity for bid item 210 does not include the length of rail on top of wall 431R.  Where will payment be made for this 155 meters of Type 80 Barrier?
 

  • Payment for 155 meters of Concrete Barrier (Type 80), which sits on top of RW 431R is accounted for in the total quantities for the Lake Hodges bridge. See contract Item No. 210(F), , CONCRETE BARRIER (TYPE 80). 


 