Inquiry #1: Can you post the mandatory pre-bid meeting attendees?
Inquiry submitted 07/18/2017

Response #1:Pre-bid meeting attendees
Response posted 07/19/2017


Response #2:Pre-bid 2nd Meeting
Response posted 08/24/2017




Inquiry #2: We are sending this Inquiry as a response to the proposed Bid date for Contract No 11-262204, Construction on State Highway in San Diego County at San Diego-Coronado Bay Bridge from Toll Gates to North Junction Route 5. We would request an extension of the proposed Bid date of no less than two (2) weeks; this is in response to the on-site visit of July 17, 2017. Upon completing the days job site visit it was demonstrated that the project entails much more deliberation concerning the logistics required to performing the tasks requested of the project. Without the requested extension an accurate assessment would be impractical. This in turn could possibly exclude us from participating in the project.
Inquiry submitted 07/19/2017

Response #1:Submitted for consideration.
Response posted 07/19/2017


Response #2:Please refer to Addendum No. 2, dated July 21, 2017.

Response posted 07/21/2017




Inquiry #3: We would like to request the agency to extend the bid date one week, to allow the potential bidders sufficient time to incorporate and accurately account for the existing field conditions logistical challenges and scope complexity that was identified at the mandatory job walk.
Inquiry submitted 07/20/2017

Response #1:Submitted for consideration.
Response posted 07/20/2017


Response #2:Please refer to Addendum No. 2, dated July 21, 2017.

Response posted 07/21/2017




Inquiry #4: We would like to request the agency to extend the bid date one week, to allow the potential bidders sufficient time to incorporate and accurately account for the existing field conditions logistical challenges and scope complexity that was identified at the mandatory job walk.
Inquiry submitted 07/20/2017

Response #1:Repeated Inquiry. Please refer to Bidder's Inquiry #3 for response.
Response posted 07/20/2017




Inquiry #5: Please provide calculations for the maximum loading weight rate capacity that can be applied to the various existing cat walk structures on this project.
Inquiry submitted 07/20/2017

Response #1:Submitted for consideration.
Response posted 07/20/2017


Response #2:Please refer to Section 5-1.37B(1) page 10 of the Special Provisions.
Loads imposed on existing platforms around piers and existing catwalks must not exceed the smaller of the following:
1. Load carrying capacity of the structure or any portion of the structure as determined by AASHTO LRFD with interims and California Amendments, Design Strength Limit State II
2. Live load of 50 psf.


Response posted 07/20/2017




Inquiry #6: Please provide calculations for the maximum loading weight rate capacity that can be applied to the various existing cat walk structures on this project.
Inquiry submitted 07/20/2017

Response #1:Repeated Inquiry. Please refer to Bidder's Inquiry #5 for response.

Response posted 07/20/2017




Inquiry #7: Sheet EE1-1 shows/ indicates the new power run from the SDGE HV manhole will traverse the road in a south easterly fashion. As discussed during the site visit, will Caltrans require the industry standard to cross the roadway at a 90 degree angle, thusly requiring a vault to be installed directly across from the SDGE HV manhole on the south side of the bridge entrance?
Inquiry submitted 07/20/2017

Response #1:Submitted for consideration.
Response posted 07/20/2017


Response #2:Please bid per the current contract documents.
Response posted 07/26/2017




Inquiry #8: The ED-1 through ED-24 sheets indicate replacement of FO60 with a single FO144 , and sheet EQ-1 indicates replacement of 1 FO cable per schedule quantity, during the site visit it was indicated an additional FO144 was required for use by the City of San Diego, will Caltrans be providing clarification to the Quantity and Lengths of the FO144 via written direction and/ or plan sheet changes?
Inquiry submitted 07/20/2017

Response #1:Submitted for consideration.
Response posted 07/20/2017


Response #2:There is NO additional FO144 cable to be installed for use by the City of San Diego across the Coronado Bridge on the Project. There will be a Fiber Optic loop installed under the HQ Structure plan sheets (EE). This work has specifications, bid item and will be paid under their bid item. The District has its own Electrical plans (E, ED and EQ) and specifications for Fiber installation which is paid under a different bid item. This is separate from the structures work. No additional District Electrical plans are being submitted.


Response posted 07/26/2017




Inquiry #9: Is there a Caltrans list of DBE Outreach Agencies available to be used in the DBE Good Faith Efforts Documentation? If so, how can it be located?
Inquiry submitted 07/21/2017

Response #1:Submitted for consideration.
Response posted 07/24/2017


Response #2:For assistance, refer to the Department's Office of Business & Economic Opportunity website: www.dot.ca.gov/hq/bep/index.htm , and the Small Business Administration website: www.sba.gov . Also, you may add yourself to the available subcontractor/supplier list for this contract by using the form for "Opt-in" at: www.dot.ca.gov/hq/esc/oe/planholders/oe_optin.php?e=11-262204

Response posted 07/28/2017




Inquiry #10: When searching for DBE Firms to fulfill our DBE Goal and complete our Good Faith Effort, are we to use the CUCP Work Category Codes or the NAICS Category and NAICS Codes?
Inquiry submitted 08/17/2017

Response #1:Submitted for consideration.
Response posted 08/17/2017


Response #2:Please bid in accordance with Section 2-1.12, ‘Disadvantaged Business Enterprises,’ of the Revised Standard Specifications (RSS). The RSS can be found in the back of the Notice to Bidders and Special Provisions book.

Section 2-1.12B(1) states in part: “You are responsible to verify at bid opening the DBE firm is certified as a DBE by the California Unified Certification Program and possesses the work codes applicable to the type of work the firm will perform on the Contract.”


Response posted 08/18/2017




Inquiry #11: Can you please provide the sign in sheet for the most recent mandatory job walk?
Inquiry submitted 08/28/2017

Response #1:Please refer to response #2 of inquiry #1.
Response posted 08/28/2017




Inquiry #12: Please confirm that the painters scaffolding will be gone by the time the awarded contractor starts work on this project. And that the contractor will be responsible for their own scaffolding for access into and out of the bridge.
Inquiry submitted 08/28/2017

Response #1:Submitted for consideration.
Response posted 08/28/2017


Response #2:Please refer to Section 5-1.32 page 9 of the Special Provisions. Access the work area from the Coronado side at Abutment 1 of the bridge. Access is available from the Highway 75 Southbound side of the bridge deck at Pier 18. This access to the upper and lower travelers is only available with a lane closure. Do not move the existing travelers. Access is also available from the roadway at Pier 33. Do not store materials or equipment at Pier 33.

Response posted 08/31/2017




Inquiry #13: Will the bridge access that is currently being used by the painters on the city side, be available for this project? In discussions with the painting contractor at the job walk, they stated that are taking it with them at the end of their contract. If it is not accessible to whoever wins this project, will Caltrans provide a 'city' side access for the contractor? And if not, what is required to construct a new temporary access for this project?
Inquiry submitted 08/31/2017

Response #1:Submitted for consideration.
Response posted 08/31/2017


Response #2:Please refer to Section 5-1.32 page 9 of the Special Provisions. Access the work area from the Coronado side at Abutment 1 of the bridge. Access is available from the Highway 75 Southbound side of the bridge deck at Pier 18. This access to the upper and lower travelers is only available with a lane closure. Do not move the existing travelers. Access is also available from the roadway at Pier 33. Do not store materials or equipment at Pier 33.

Response posted 08/31/2017




Inquiry #14: During the painters box support structure installation, is false work required because of work under the catwalk?
Inquiry submitted 09/06/2017

Response #1:Submitted for consideration.
Response posted 09/07/2017


Response #2:Falsework is not required.
Response posted 09/08/2017




Inquiry #15: Plan sheet EE6-1 to EE6-5 note 2 calls to remove existing armored cable and replace with PRJ.
Sheet EE6-5 note 7 says secure cable to bridge members and terminate PRJ for pier 18 480v control center. See plan Sheet EE4-1.
Plan sheet EE4-1 note 27 says existing armored cable to remain as spaced.
Please advise where to terminate PRJ in 480v control center. In Reviewing Sheet EE0-4, one line diagram does not show painters circuit A landing inside of control center.

Inquiry submitted 09/07/2017

Response #1:Submitted for consideration.
Response posted 09/08/2017


Response #2:a. Please refer to note 2 on sheets EE6-1 to EE6-5 and note 7 on EE6-5. Please bid per the current contract documents.

b. Please bid per the current contract documents.

c. Please refer to note 15 and 18 on EE0-4. Please bid per the current contract documents.

Response posted 09/11/2017




Inquiry #16: For the PLC, Will Caltrans waive the CSIA certification requirement if the integrator shows experience acceptable to Caltrans?
Inquiry submitted 09/07/2017

Response #1:Submitted for consideration.
Response posted 09/08/2017


Response #2:Please bid per the current contract documents.
Response posted 09/12/2017




Inquiry #17: Can the metal wire raceway covers be left on the catwalk or do they have to be taken off the bridge when not fastened?
Inquiry submitted 09/07/2017

Response #1:Submitted for consideration.
Response posted 09/08/2017


Response #2:The metal wire raceway covers could be left on the catwalk or be taken off the bridge during the installation of conductors in the raceway, as long as they are handled in a safe and secure manner and must not; become a trip hazard on the catwalk, be vulnerable to any physical damage, and lose their integrity. Each cover must be reinstalled at its existing location.


Response posted 09/11/2017




Inquiry #18: Should the SDGE plans found in the information handout documents, be used for bid purposes?
Inquiry submitted 09/07/2017

Response #1:Submitted for consideration.
Response posted 09/08/2017


Response #2:Supplemental Project Information is a contract component. Please refer to Section 2 "Bidding" of the Special Provisions.


Response posted 09/08/2017




Inquiry #19: For Bid Item number 40 - Public Safety Plan. Can you please specify the exact requirements you want pertaining to this project? Caltrans specifications only mention providing a plan when treating bridge decks or other structures with chemicals or sealants.
Inquiry submitted 09/11/2017

Response #1:Submitted for consideration.
Response posted 09/11/2017


Response #2:Please bid per the current contract documents.
Response posted 09/12/2017






The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.07, “JOB SITE AND DOCUMENT EXAMINATION” of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.