| CONTRACT NO: | 11-2T1804 |
| ROUTE / PM | 11-SD-805-9.4/13.8 |
| LOCATION | In San Diego County In San Diego And National City From 0.6 Mile North Of Route 805/54 Separation To 0.2 Mile North Of Federal Boulevard Undercrossing. |
| DESCRIPTION | Construct North And South Bound Hov Lanes. |
| CONTRACT TYPE | A + B Bidding |
| ESTIMATE | $22,100,000 |
| WORKING
DAYS |
420 |
| ADVERTISE DATE | 01/17/2012 |
| BID OPENING | 03/08/2012 |
| FINAL POSTING |
03/07/2012@ 09:40
|
The Caltrans District
11 Office is located at 4050 Taylor Street, San Diego, CA 92110. The
District 11 Duty Senior telephone number is (619) 688-6635. Please
submit all inquiries in the proper format by fax to (619) 688-6988 or
e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to
bidder' inquiries, unless incorporated into a formal addenda to the
contract, are not a part of the contract and are provided for the
bidder's convenience only. In some instances, the question and answer
may represent a summary of the matters discussed rather than a
word-for-word recitation. The responses may be considered along with
all other information furnished to prospective bidders for the purpose
of bidding on the project. The availability or use of information
provided in the responses to bidder' inquiries is not to be construed
in any way as a waiver of the provisions of Section 2-1.03 of the
Standard Specifications or any other provision of the contract, the
plans, Standard Specifications or Special Provisions, nor to excuse the
contractor from full compliance with those contract requirements.
Bidders are cautioned that subsequent responses or contract addenda may
affect or vary a response previously given.
Caltrans District 11 Construction
Department has developed this method of answering Bidder's Inquiries to
better serve the needs of the Contractors who bid on our Projects.
Caltrans District 11 Construction Department will post all of the
questions submitted by any of the contractors that are registered
Planholders for that Contract, but reserves the right to not answer any
questions deemed unsatisfactory for public viewing.
The BIDDER'S
INQUIRIES & RESPONSES will be updated continuously and all attempts
will be made to do the final posting by 15:00 on the day prior to the
bid opening. However, to allow the Department
reasonable time to review and respond, bidders are recommended to send
in their inquiries at least four (4) working days prior to the bid
opening.
INFORMATION
AVAILABLE
|
|
|
|
|
|
|
|
|
ORDERING
PROJECT PLANS AND SPECIFICATIONS
ADDENDUM
| ADDENDUM #2 |
|
BIDDER'S INQUIRY SUBMITTAL FORM
|
|
Inquiry |
|
1 Q:02/20/12 |
Plan Sheet / Specification Reference= Staged Construction Plans and new standard plan NSP T3A Question = The staged construction plans show that the edge of excavation will be 1.5' from back of temp railing type K. The new standard plan T3A is included in the project plans. Will all the K rail be required to be staked per this plan when the excavation is 1.5' from back of K rail? If yes, will the State allow the use of all thread bolts and a threaded nut to hold the washer to the K rail?
|
|
2 Q:03/01/12 |
Plan Sheet / Specification Reference= Special Provision Question =
According to the bid item list there are 920’ of Concrete Barrier Type
60 Mod. Where can the detail for this modified wall be found in the
plans?
|
|
3 Q:03/01/12 |
Plan Sheet / Specification Reference= Var Question = 1- Ref Item 67, Plan detail sheet C-1(38/346), Quantity Summary sheet Q-1(277/346), and the various Layout plan sheets and Electrical Plan sheets. Please take a look at what you require for this barrier on C-1, and the limits called out for on the layouts and quantity summary sheets. Confirm your intent to build this roller coaster barrier, with elevation changes at each electrolier. 2- Same stuff as ref above. Per the " Limit of
Payment" note on the detail plan, C-1, Type 60RC will have a limit of
approx. 78'-8" lft. Per the Electrolier spacing on E-7 E-8 amd E-9, of
approx. 200 LFT there will be approximately 102 lft not measured and
paid as Type 60 RC barrier. Will you clarify the " Limit of Payment"
please?
|
4 Q:03/06/12 |
Plan Sheet / Specification Reference= Question =1-Ref Addendum #2- The information shown is missing dimensional details for barrier width, top and bottom; side slopes, and quantification. Additionally there are 17 locations called for on Plan Sheet SDS-1, but the quantification for Item 69, shown on Plan Sheet 277 is for only 12 locations @ 76 LFT/ea. Will this ambiguity be clarified before bid by another addendum? 2- Ref your earlier response to pre bid inquiry # 3 parts 1 and 2- We disagree with the answer, as your "check" appears to be incomplete. This Item 67 as currently presented in the bid documents is ambiguous,and conflicting. 3- Clarify if the Concrete Barrier Transitions shown on Plan Sheet 41, upper right hand side of the sheet, for 6 locations at Overhead Sign Foundations are to be constructed without galvanized steel closure plates, similar to Concrete barrier Type 60 E Standard Plan A 76C at Sign Pedestals.
|
5 Q:03/06/12 |
Plan Sheet / Specification Reference= Special Provision Section 5-1.10 Question =Please add reinforcing steel to the listed materials to be included in payment as materials furnished but not incorporated in the work.
|
6 Q:03/06/12 |
Plan Sheet / Specification Reference= 36, Jointed Plain Concrete pavement, 317, RSP-P18 Question = Revised Standard Plan P-18 (Case 1) shows a longitudinal joint with tie bars between new concrete lane and new concrete shoulder. Please confirm Case 1 applies to this project.
|