| CONTRACT NO: | 11-257144 |
| ROUTE / PM | 11-SD-15, 76-R46.1/R47.3,R16.7/R17.7 |
| LOCATION | In San Diego County Near Bonsall And Fallbrook On Route 15 From 0.4 Mile South To 0.8 Mile North Of Route 76/15 Separation And On Route 76 From 0.5 Mile West To 0.5 Mile East Of Route 76/15 Separation. |
| DESCRIPTION | Modify And Widen Interchange. |
| CONTRACT TYPE | A + B Bidding |
| ESTIMATE | $24,400,000 |
| WORKING
DAYS |
665 |
| ADVERTISE DATE | 05/21/2012 |
| BID OPENING | 07/19/2012 |
| FINAL
POSTING |
07/19/2012
@ 12:10
|
The Caltrans District
11 Office is located at 4050 Taylor Street, San Diego, CA 92110. The
District 11 Duty Senior telephone number is (619) 688-6635. Please
submit all inquiries in the proper format by fax to (619) 688-6988 or
e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to bidder' inquiries,
unless incorporated into a formal addenda to the contract, are not a
part of the contract and are provided for the bidder's convenience
only. In some instances, the question and answer may represent a
summary of the matters discussed rather than a word-for-word
recitation. The responses may be considered along with all other
information furnished to prospective bidders for the purpose of bidding
on the project. The availability or use of information provided in the
responses to bidder' inquiries is not to be construed in any way as a
waiver of the provisions of Section 2-1.03 of the Standard
Specifications or any other provision of the contract, the plans,
Standard Specifications or Special Provisions, nor to excuse the
contractor from full compliance with those contract requirements.
Bidders are cautioned that subsequent responses or contract addenda may
affect or vary a response previously given.
Caltrans
District 11 Construction Department has developed this method of
answering Bidder's Inquiries to better serve the needs of the
Contractors who bid on our Projects. Caltrans District 11 Construction
Department will post all of the questions submitted by any of the
contractors that are registered Planholders for that Contract, but
reserves the right to not answer any questions deemed unsatisfactory
for public viewing.
The BIDDER'S INQUIRIES & RESPONSES
will be updated continuously and all attempts will be made to do the
final posting by 15:00 on the day prior to the bid opening. However, to
allow the Department reasonable time to review and respond, bidders are
recommended to send in their inquiries at least four (4) working days
prior to the bid opening.
INFORMATION
AVAILABLE
|
|
||||
|
X-SECTIONS |
|
ORDERING
PROJECT PLANS AND SPECIFICATIONS
ADDENDUM
ADDENDUM#1 |
ADDENDUM#2 |
|
BIDDER'S INQUIRY SUBMITTAL FORM
|
|
Inquiry |
|
1 Q:05/21/12 |
Plan Sheet / Specification Reference= Special Provision Section 5-1.12 Supplemental Project Information Question= Special Provision Section 5-1.12 Supplemental Project Information page 44, states that cross sections are available for this project. When will the cross sections be posted and available for our download and use?
|
2 Q:06/05/12 R:06/29/12
|
Plan Sheet / Specification Reference= Reference section 5-1.16 (CRWQCB) requirements. Question= Is a copy of the 401 certification permit available?
|
3 Q:06/25/12 R:06/26/12
|
Plan Sheet / Specification Reference= General Question Question= I don't see any "Buy America" requirements listed on this project, Does that mean that there are none?
|
4 Q:07/03/12
|
Plan Sheet / Specification Reference= Item 79, Erosion Control (Polymer Stabilized Fiber Matrix), 298-310, 10-1.46 Question= Per the manufactures recommended application rates 10 gal per acre is the maximum rate of application, Specs state to apply 84 gal per acre.
|
5 Q:07/09/12 |
Plan Sheet / Specification
Reference= Bid item number 145 - 148 Alternative pipe, APC allowable Pipe
Question= APC Spec calls out for spiral ribbed with polymeric sheet coating and polymerized assault invert. Is polymeric trenchcoat acceptable, polymeric sheeted with asphalt invert is no longer commercially available?
|
6 Q:07/18/12 |
Plan Sheet / Specification
Reference= Plan Sheets 472 to 474
Question= Plans sheets 472-474 show a detail of "log of test borings" for the project. Please clarify if this information is representation for work in the entire project?
|
7 Q:07/18/12 |
Plan Sheet / Specification
Reference=
Question= Q #1: Section 8-1.02 “State Furnished Materials” of the Special Provisions are not consistent to all the materials identified to be furnished under section 10-3 of the Special Provisions. Please clarify.
Q #3: Section 10-3.07 refers to the plans for a “T” trench detail. None are shown on the project electrical plans. Please clarify.
Q #4: Section 10-3.19 subsection “fiberglass communication conduit” provides
specifications for “fiberglass conduit” and its conformance to the details shown
on the plans. However there are no fiberglass details shown on the electrical
Q #5: Plan sheet 471 detail the installation of the communication conduit in the bridge. However, there are no corresponding electrical plan details for the installation to the material (i.e.: hanger rod, clamps and utility bracket) shown on the sheet. Please clarify the method of payment and specifications requirements for the mounting assembly since there is no language in the electrical.
|
8 Q:07/18/12 |
Plan Sheet / Specification
Reference= Contract plan sheet 461, CIDH pile detail for 24" diameter shaft
Question= Current rebar desing does not meet current Caltrans desing standards for 5" x 5" window clearance between vertical #11 bars. As well as curretn desing stadnards for clearance of 3" between PVC inspection tube and vertical rebar. Cage needs to be redesigned before constrcution starts.
|
9 Q:07/18/12 |
Plan Sheet / Specification
Reference= Special Provisions, page 226
Question= Under placing concrete, Item 'A'; pump placement of concrete thru 10" tremie will not work in a 18" OD rebar cage, with PVC inspection tubes. Will the option of a 5" tremei be allowed as an addendum for this project.
|
10 Q:07/19/12 |
Plan Sheet / Specification
Reference=
Question= Q #1: Section 10-3.23 “Payment” of the Special Provisions indicates the payment of “interconnection conduit and cable” plan sheet or scope work to be paid under
count station. However, there are no plans designated with such title and the
|