BIDDER'S INQUIRIES & RESPONSES
DISTRICT 11 CONSTRUCTION

 
CONTRACT NO: 11-010614
ROUTE / KP 11-SD-52,67,125-Var
LOCATION In San Diego County At Various Locations.
DESCRIPTION Construct A Four-lane Freeway.
ESTIMATE $ 74,000,000
WORKING DAYS
965 (Including 250 Working Days of Plant Establishment)
ADVERTISE DATE 09/24/2007
BID OPENING 11/15/2007
FINAL POSTING

11/14/07   @    16:00


BID RESULTS


The Caltrans District 11 Office is located at 4050 Taylor Street, San Diego, CA 92110. The District 11 Duty Senior telephone number is (619) 688-6635. Please submit all inquiries in the proper format by fax to (619) 688-6988 or e-mail to:

Duty_Senior_Const_District11@dot.ca.gov.
The responses to bidder' inquiries, unless incorporated into a formal addenda to the contract, are not a part of the contract and are provided for the bidder's convenience only. In some instances, the question and answer may represent a summary of the matters discussed rather than a word-for-word recitation. The responses may be considered along with all other information furnished to prospective bidders for the purpose of bidding on the project. The availability or use of information provided in the responses to bidder' inquiries is not to be construed in any way as a waiver of the provisions of Section 2-1.03 of the Standard Specifications or any other provision of the contract, the plans, Standard Specifications or Special Provisions, nor to excuse the contractor from full compliance with those contract requirements. Bidders are cautioned that subsequent responses or contract addenda may affect or vary a response previously given.
Caltrans District 11 Construction Department has developed this method of answering Bidder's Inquiries to better serve the needs of the Contractors who bid on our Projects. Caltrans District 11 Construction Department will post all of the questions submitted by any of the contractors that are registered Planholders for that Contract, but reserves the right to not answer any questions deemed unsatisfactory for public viewing.
The BIDDER'S INQUIRIES & RESPONSES will be updated continuously and all attempts will be made to do the final posting by 15:00 on Wednesday prior to the bid opening.
INFORMATION AVAILABLE
 

BID ITEMS
 SPECIALS
PLANS
 PLANHOLDERS
INFORMATION HANDOUTS
PART 1

Last Updated
10/01/07

INFORMATION HANDOUTS
PART 2

Last Updated
10/01/07

INFORMATION HANDOUTS
PART 3
Last Updated
10/09/07
INFORMATION HANDOUTS
PART 4
Last Updated
11/09/07


CROSS SECTIONS CROSS SECTIONS
Last Updated
10/29/07




ADDENDUM


 
 
 
 

BIDDER'S INQUIRY SUBMITTAL FORM


Inquiry No.
Inquiry

1

   Q:09/26/07
  R:09/27/07

Plan Sheet / Specification Reference=

Question= will cross section be available for this project?
there is a link, however when you click on it, it says forbidden.

  • Cross sections are available as of 9/27/07 and can be downloaded for printing from the link above at any local printing firm or on your own printing equipment:

     MESA BLUEPRINT 
     5560 Ruffin Road Suite 5 
     San Diego, CA 92123 
     (858) 541-1500    FAX (858) 278-0558 
     e-mail to  plot@mesablueprint.com San Diego, CA 92123

 

 
2

   Q:09/26/07
   R:10/01/07
Plan Sheet / Specification Reference= Fanita creek br. no. 57-1132

Question= where are the drawing for the fanita creek bridge?

  • Any structure wider than 20' is always assigned a Bridge No. Please refer to sheet 99, D-5 and sheet 111, DP-6.      
  
3

   Q:10/02/07
  R:10/11/07
Plan Sheet / Specification Reference= Plan Sheet #559, 577 - 579, and Specification Section 10-1.39 Earth Retaining Structures; snetence beginning "The architectural features ..............on the plans."

Question= Plan sheet 569 calls out a cobblestone finish for the panels. Plan sheets 577- 579 detail a raised surface detail.

1. What finish does the owner erquire?
  • The Architectural Treatment (Cobblestone Texture) under the Quantities heading on plan sheet 569 refers to the architectural treatment for the concrete barrier located on top of the MSE walls. Please see plan sheet 582 for the location of the Architectural Texture (stained cobblestone) at the concrete barrier.
  • Raised areas of the MSE panels indicated on the plan sheets 577-579 are correctly shown and cobblestone texture is not to be used for these MSE panels. Please refer to Section 10-1.39 Earth Retaining Structures of the Special Provisions for architectural treatment of the MSE panels.

2. Is the cobblestone finish from a particular form liner supplier or is a general statement of appearance such as similar to river rock?

  • The cobblestone finish is not from a particular form liner supplier. For texture specifications, please see Section 10-1.61 Architectural Treatment of the Special Provisions.       


 

 

 

4

   Q:10/03/07
   R:11/02/07

Plan Sheet / Specification Reference= Earth work, Imported Borrow, Cross sections.

Question= The Forester creek contractor is stockpiling material on top of the existing embankment located in the 52 alignment, do the avaiable cross sections show this embankment and if not are you going to up the cross sections to reflect these changes.

  • Yes, the Contractor working on the City of Santee’s Contract for improvements to Forester Creek has placed material within the State’s Right of Way between Stations 1256+20 to 1261+02. This material was placed and tested in accordance with Caltrans Section 19 of the Standard Specifications to a 90% Relative Compaction and no addition material will be placed after October 25, 2007. The revised quantities for the Roadway Excavation and Import Borrow Items in Addendum No. 1, dated October 25, 2007, reflect the change to the Original Ground between Stations 1256+20 to 1261+02 for bidding the items listed above. The revised Cross Sections are available for download from the link above dated 10/29/07 and supersede the cross sections between Stations 1256+20 to 1261+02 only. The contractor will be required to do no addition work other than that is already required to prepare Original Ground to accept embankment Material and clear and grubbing as determined by the Engineer. However, the material may be placed outside the line and grade of this Contract's Roadway prism and may generate localized areas of surplus material that should be considered when balancing dirt on this project.



5

   Q:10/03/07
  R:10/03/07
Plan Sheet / Specification Reference= Fanita Drive UC

Question= Please clarify your your answer to Question # 2.  The drawing sheets indicated do not provide any details for the Fanita Drive UC.  Where can the details for this bridge be found in order for it to be quantified.  Is the Fanita Drive UC a part of this contract?
  • Please refer to Question #6.

6

   Q:10/03/07
  R:10/03/07
Plan Sheet / Specification Reference= Fanita Dr UC

Question= I withdraw the previously submitted question in regards to this bridge structure.
  • Thank you.


7

   Q:10/08/07
  R:XX/XX/07

Plan Sheet / Specification Reference= Bid Item 97 - Structural Concrete, Bridge

Question= The "Structure List" on sheet 1 of 591, has listed the following structure: No. 6, Fanita Creek (NOT Fanita Drive UC), Bridge  No. 57-1132.  In reviewing all of the contract drawings, I find no details for this structure to be able to quantify it.  Are these details forthcoming, or is this bridge NOT a part of the contract.

The subject of this bridge was brought up in question # 2, but no conctreye answer was given
  • Fanita Creek (Br No. 57-1132) structure is Drainage System No. 12.  The width of the drainage system is wider than 20' thus, a Bridge No. was assigned to it. Please refer to sheet 13, L-6, sheet 99, D-5 and sheet 111, DP-6.

 

8
  

Q:10/08/07
R:11/08/07

Plan Sheet / Specification Reference=ITEMS 55-58, EARTH RETAINING STRUCTURES
SECTION 10-1.39

Question= The special provisions discuss "drainage system" associated with these items, yet we do not see them in the plans.  Please clarify.

  • These MSE walls do not require any underdrains. Therefore, there are no drainage systems.


9

   Q:10/19/07
  R:11/08/07

Plan Sheet / Specification Reference=84 DRIVE STEEL PILE (HP 360 X 132)
86 DRIVE STEEL PILE (HP 360 X 174) 94 DRIVE PILE (CLASS 400)

Question=Are there any kind of Load Tests required for this project? If so, how many and what kind?

  • Contract plans and special provisions do not require load testing.




10

   Q:10/19/07
  R:11/08/07

Plan Sheet / Specification Reference=Special Provision 10-1.01 (Page 181)and Special Provision 10-1.16 (Page 215)

Question=Both Special Provision 10-1.01 (Page 181)and Special Provision
10-1.16 (Page 215) indicate that a designated lane has been designed for
crossing of materials hauling equipment on "A. West 52 - South 125
Connector, Bridge No. 57-1096F."
Did the Special Provisions really mean to read "A. Route 52/125
Separation, Bridge No. 57-1096R?"

  • It should read Route 52/125 Separation, Bridge No. 57-1096R in lieu of West 52 - South 125 Connector , Bridge No. 57-1096F.






 

11

   Q:10/19/07
  R:11/08/07

Plan Sheet / Specification Reference=Bid Item 59 - Imported Borrow - 246,000 M3 Special Provision 10-1.17 Cooperation (Page 216) Special Provision 10-1.01 Order of Work (Page 180)

Question=Specification 10-1.17 Cooperation indicates "It is anticipated
that work by another contractor... may be in progress adjacent to or
within the limits of this project during progress of the work on this
contract."

  • For future Unit 5B.

To what extent will another contractor be working within the limits of
this project? 

  • In the area of Cuyamaca Street, Unit 5B, with estimated construction start time of 02/09.

Were the bridges described in Special Provision 10-1.01
as a first order of work designed for materials hauling because another
contractor is going to be hauling material through the project? 

  • No.

Does Caltrans desire excess material from a future Route 52 project hauled
into or through this Route 52 project?

  • No.


 

12

   Q:10/29/07
  R:10/29/07

Plan Sheet / Specification Reference= Addendum 1, plan sheets 23,24,28 and 29

Question= When will the revised cross sections be issued to support the changes as shown on plan sheets 23,24,28 and 29 in addendum No. 1. Without revised cross sections or new grading plans, we are unable to determine what changes were made.
  • The updated cross sections are available as of 10/29/07 and can be downloaded for printing from the link above at any local printing firm or on your own printing equipment:

MESA BLUEPRINT 
     5560 Ruffin Road Suite 5 
     San Diego, CA 92123 
     (858) 541-1500    FAX (858) 278-0558 
     e-mail to  plot@mesablueprint.com San Diego, CA 92123



 

13

   Q:10/30/07
  R:10/31/07

Plan Sheet / Specification Reference=  87-92, CIDH Piling, 10-1.53 Piling

Question= Can you provide contact information for the Transportation
Laboratory for the purpose of viewing cores?
  • Please contact the following people for arrangements:
          Primary Contact
          David Thomas at (916) 227-5450 or (916) 240-3821

          Secondary Contact
          Mohan Bonala at (916) 227-1053


14

   Q:11/01/07
  R:11/07/07

R:11/08/07



Plan Sheet / Specification Reference= Bid 68 Water Meter 4 ea

Question= Page 363 Water meter supplied by Padre Dam water District and paid for by the contractor @ $27,000.00. Does that include all four water meters or is that only for one meter.
  • Page 363 of the Special Provisions states that "The Padre Dam Municipal Water District has established a fee of $27,000 for furnishing and installing a water meter." Please refer to section 10-2.05 "IRRIGATION SYSTEMS," "WATER METER" of the Special Provisions.


15

   Q:11/02/07
  R:11/08/07

Plan Sheet / Specification Reference= 155 (S) TELEVISING SEWER MAIN, SP SECTION 10-4.01 TELEVISING SEWER MAINS

Question= Please identify which sewer or sewers are to be televised under which bridges?

  • All sewer lines.


16

   Q:11/05/07
  R:11/06/07

Plan Sheet / Specification Reference= 86(S) DRIVE STEEL PILE (HP 360 X 174), 453, 10-1.53 PILING

Question= According to page 298 of the Special Provisions the elevation of bottom of hole for the N125-E52 Connector is 103 m. However, the bottom of footing elevation for Abutment 2 shown on plan sheet 453 is 102.97 m. Please confirm the bottom of predrilled hole elevation for the N125-E52 Connector.
  • Please bid per the current contract documents.


17

   Q:11/07/07
  R:11/14/07

Plan Sheet / Specification Reference= 90 - 3.0M CIDH, Plan Sheets 383,
404 and 423/591.

Question= What does the 5.0 m dimension callout below pile cut-off
elevation represent?

  • The 5 meter callout is to show the distance that Section C-C is used in. Below the 5 meter callout is section D-D. Section C-C has the same number of bars as section B-B, just closer. Section D-D has fewer bars.



18

   Q:11/07/07
  R:11/13/07

Plan Sheet / Specification Reference= 89 - 2.3M CIDH, Plan Sheet 481/591

Question= The plans for Forester Creek, sheet 481/591, shows an allowable
construction joint at the base of column reinforcement.  Will it be
allowable to leave casing in place over the depth of column
reinforcement plus 0.5 m for overlap?  If it is allowable, what amount
of oversizing the diameter is allowable?  Is there a preferance for
smooth wall or CMP?

  • Please bid per the current contract documents.


19

   Q:11/07/07
  R:11/13/07

Plan Sheet / Specification Reference= 90 - 3.0M CIDH, Plan Sheets 383,
404 and 423/591.

Question= Is a construction joint at the base of column reinforcement
allowable?  If so, will it be allowable to leave casing in place over
the depth of column reinforcement plus 0.5 m for overlap?  What amount
of oversizing the pile diameter is allowable?  Is there a preferance for
smooth wall or CMP?

  • The bid opening date is 11/15/2007 and there is no time to issue an addendum. Please Bid per the current contract bid documents.


20

   Q:11/07/07
  R:11/09/07

Plan Sheet / Specification Reference= Item # 76 - Asphalt Paving.  Page C-1
Construction Details

Question= Just for clarification purposes, on page C-1 (Construction
Details), there is a cross hatched area that says "COLD PLANE 30mm to 90mm"
with no mention of overlaying the area with asphalt.  Is the area indicated
by that cross hatch symbol to be overlaid with asphalt at the same depth as
it is being taken out? And is that amount of asphalt included in the
quantities that were provided?

  • Please bid per the current contract documents.


 

21

   Q:11/07/07
  R:11/13/07

Plan Sheet / Specification Reference= BI #89 & 90, CIDH pile connections to Column. Plan sheets 383, 404, 423, & 481, Bent 2 details and column details.

Question= Sheet 481, Pier details for Forester Creek Bridge, shown optional Constuciton Joint at bottom of column cage embed.  Details for Mission Gorge (Sht. 383), Rte. 52/125 (Sht. 404) and West 52-South 125 (Sht. 423) bridge supports do not.  Will it be accptable for an a C.J. in all of these other column to CIDH pile connections?

Also, to allow for a C.J. will permanent pipe, CMP or steel smooth wall, be acceptable to be left in place to a minimum of 5'ft. below the C.J.??

  • The bid opening date is 11/15/2007 and there is no time to issue an addendum. Please Bid per the current contract bid documents.


22

   Q:11/07/07
  R:11/09/07

Plan Sheet / Specification Reference= B.I.'s #83 thru #94

Question= Are thier any rock core strength breaks avaiable on any of the borings taken on this project?

  • Rock core strength breaks are not available.

 

 

23

   Q:11/08/07
  R:11/XX/07

Plan Sheet / Specification Reference=ITEM #215 (S) Catenary Work - Phase 1 & 216 (S) Catenary Work Phase 2. Railroad plans RR-4 thru RR-12 (Sheet 317 thru 325) Special Provisions Section 10-5 Railroad Construction. Section 10-5.11 OCS Material & Equipment.

Question= On plan sheet RR-4 catenary phase 1 and RR-4 catenary phase 2 it calls out for certain catenary assemblies to be furnished however if you go to the sheet RR-10 thru RR-12 there are no details for the assemblies. The assemblies in question are 32-1, 32-4, 35-1, 43-2 and 43-4. Can you please provide detail for these assemblies. Also, On Sheet RR-12, in the bill of materials (Schedule) it shows assembly types 3, 6 and 7 however if you look at the details on the same sheet it only displays assembly type 34-1 & 34-2. Please provide detail for other assembly type.

  • Please reference INFORMATION HANDOUTS PART 4 link.                                                                                                                                                                                                

 

 

24

   Q:11/09/07
  R:11/09/07

Plan Sheet / Specification Reference=Final Foundation Reommendations MEMORANDUMS...regarding CIDH Rock Sockets

Question= Serveral Memorandum refer to the geotechnical capacity of the CIDH piles based on Friction ONLY!  However, the bottom of the drilled holes is to be cleaned out, INPSECTED AND APPROVED by the engineer, prior to the placment of the drilled reinforcement cage and concrete.

How does the on-site engineer inspect a rock socket bottom and approved when the CIDH is under water?

  • The Special Provisions, Section 10-1.53 "Piling", Subsection "Cast-In-Drilled-Hole Concrete Piles", states: "Cast-in-drilled-hole concrete piling (rock socket) shall consist of drilling or coring sockets in rock to the depths or lengths specified and filling with reinforced concrete in conformance with the details shown on the plans and these special provisions. Cored holes, if used, shall conform to the provisions of Section 49-4.03, "Drilled Holes," of the Standard Specifications."Section 49-4.03 "Drilled Holes,"of the Standard Specifications states:
    The bottom of the drilled hole shall be cleaned just before placing reinforcement or concrete to remove any loose sand, gravel, dirt, and drill cuttings. The field acceptance is subject to Section 5-1.01 "Authority of the Engineer" of the Standard Specifications. Bid per the current contract bid documents.

                                                                                                                                                                                          

 

 

25

   Q:11/09/07
  R:11/09/07

Plan Sheet / Specification Reference=Plan Sheet / Specification Reference=Traffic Handling Plan sheets 188 thru 203 and Special Provisions sheets #233 thru 243.

Question=Current traffic plans and lanes closures make it very difficult for public saftey and the construction of the 3.0M CIDH piles @ Mission Gorge Rd. UC & Rte. 52/125 Separation. The current amount of working lanes (room) makes it very restirctive for the Large drilling equipment that wil be needed to drill these rock sockets.

At a minimum, Can Traffic Chart #6 (Special Provisions Sheet 238) be applied during the drilling operations on Mission Gorge. Likewise, at SR125 can Traffic Charts 236 & 237 be apply during the CIDH drilling there.

  • Please bid per the current contract documents.

 


26

   Q:11/09/07
  R:11/14/07

Plan Sheet / Specification Reference= B.I.91 (S) & 92 (S) CIDH Piling (Rock Socket)

Question= Will blasting (or similar industry methods) be allowed for excavation of the 'rock' in the CIDH Pile rock sockets?

  • No.

27

   Q:11/12/07
  R:11/13/07

Plan Sheet / Specification Reference=

Question= Regarding Item # 171 “Chain Link Gate” 13 each. Gates widths are not given on either the engineers estimate nor on the construction plans could you please elaborate.  

  • Please refer to A 85 "CHAIN LINK FENCE" of the 2004 Standard Plans.
        

28

   Q:11/12/07
  R:11/14/07

Plan Sheet / Specification Reference= Reply by Caltrans to Question #22 of the Bidder's Inquires & Responses.

Question= Since rock core breaks are not available, we must assume the rock strengths on this project are derived from the descriptive relative strength words used in the LOTB.  If so, can we expect where granite is described as 'extrememly hard,' the range of possible strengths would be at a minimum 32,000PSI?

  • According to the "Soil and Rock Logging, Classification, and Presentation Manual" dated June 2007, page 70, Rock Hardness with a descriptor "Extremely Hard" used in the Log of Test Borings has the following criteria:
"Specimen cannot be scratched with pocket knife or sharp pick; can only be chipped with repeated heavy hammer blows."

Manual can be accessed through the following Caltrans website:

http://www.dot.ca.gov/hq/esc/geotech/requests/logging_manual/logging_manual.html


29

   Q:11/12/07
  R:11/14/07

Plan Sheet / Specification Reference= Items 89 & 91, Pier 2, Pile 2, Bridge 57-1100, Pile data table on sheet 469

Question= The pile data table identifies a 4M rock socket with top of estimated hard rock at elevation 80.5.  The boring nearest this shaft (Boring B-2 on sheet 502)  identifies top of granite at approximate elevation 93M.  This is a 12.5M elevation difference.  Please confirm that the rock socket bid item unit price will be paid from the top of hard rock actually encountered.  

  • We expect hard rock at the elevations listed in the Pile Data Table.  Any increases or decreases in the quantity of CIDH (Rock Socket) will be determined by the Engineer in the field.  Changes in quantities shall be in conformance with the Standard Specifications, Section 4-1.03B, "Increased or Decreased Quantities."

 

 

30

   Q:11/13/07
  R:11/13/07

Plan Sheet / Specification Reference= Item170- Chain Link Fence (Type CL-1.8, Vinyl-Clad)


Question= The Special Provisions on page 346 indicate that only the chain link fabric is to be vinyl-clad. Is that the intent?

  • Yes.

Or is the intent to have all the material vinyl clad?

  • NO.

 

 

 

31

   Q:11/13/07
  R:11/13/07

Plan Sheet / Specification Reference=Plan Sheet No. 318 of 591 RR-5

Question=1- WILL CONSTRUCTION OF THE FALSE WORK OVER THE CATENARY SYSTEM BETWEEN STA 30+33.980 AND 30+83.420 HAVE TO BE CONSTRUCTED DURING NON REVENUE HOURS. NOTE 3 REQUIRES ALL CATENARY WORK TO BE DONE UNDER THIS WINDOW. NOTE 5 DISCUSSES THE FALSE WORK. THIS WORK APPEARS TO BE WITH IN THE CAL OSHA REQUIREMENTS OF WORKING CLEARANCES OF ENERGIZED LINES.

2- IF THIS WORK IS TO BE PERFORMED UNDER THIS WINDOW, WHAT ARE THE WORKING HOURS.  TYPICAL CATENARY WORK HOURS IN THIS AREA ARE 12:30AM TO 4:AM EXCLUDING SPECIAL EVENTS (PADRE AND CHARGER GAMES ETC)

  • Please refer to section 10-5.13.1 "WORK ON AND UNDER AN EXISTING ENERGIZED LRT SYSTEM" of the Special Provisions:
  • 10-5.13.1 WORK ON AND UNDER AN EXISTING ENERGIZED LRT SYSTEM
    The existing traction power system is rated at 650 V DC nominal. SDTL considers this system "High Voltage." The Contractor’s work shall be performed in accordance with the provisions of SDTL and the "High Voltage" provisions of the
    California Administrative Code. The Contractor shall adapt all equipment and installation methods to this condition, and shall take due precautions against accidents and damage to SDTL equipment, facilities and/or materials. Without exception, all work on or affecting the existing catenary system overhead wires shall be performed with the system fully de-energized. The system will be de-energized only by SDTL personnel under their rules. Full compensation for complying with all the requirements for work on and under an existing, energized LRT system not
    specifically identified and described in the measurement and payment clauses of these special provisions shall be considered as incidental and included in the Contract prices paid for the various related items of work and no additional compensation will be allowed therefore.

 

 

32

   Q:11/12/07
  R:11/14/07

Plan Sheet / Specification Reference=

Question= The plan sheets you provided do provide the assembly details I requested in my Bidders Inquiry, however some of the other plan sheets provided are confusing me.   sheets TP-478 and TP-479 are referring to Station Locations from 986+50 thru 1006+20 and the original project plans are referring to Station Locations 28+57.890 thru 32+65.170 on Plan Sheets RR-4 & RR-6.   Please advise.

  • Following are the English Stations in relations to the Metric.
·    Pole at sta 977+05 (sta 28+57.89 'cs')    
·    Pole at sta. 978+31 (sta. 28+95.92'cs' )    
·    Pole at sta. 980+37 (sta. 29+59.09 'cs')    
·    Pole at sta. 982+40 (sta. 30+20.98 'cs')    
·    Pole at sta. 984+45 (sta. 30+83.42 'cs')    
·    Pole at sta. 986+50 (sta. 31+45.99 'cs')    
     Pole at approx station 32+08.478 'cs'