BIDDER'S INQUIRIES & RESPONSES
DISTRICT 11 CONSTRUCTION

 
CONTRACT NO:  11-080944
ROUTE / KP 11-SD-15-M30.0/M44.6
LOCATION In San Diego County In San Diego And Escondido From 0.7 Km North Of Poway Road Overcrossing To 0.1 Km South Of Clarence Lane Undercrossing.
DESCRIPTION Construct Additional Lanes, Movable Barriers, And Replace Bridges
ESTIMATE $ 37,100,000
ADVERTISE DATE 02/14/2006
BID OPENING 04/13/06
05/18/06
FINAL POSTING 05/17/06    @   16:15

BID RESULTS

1
FCI CONSTRUCTORS, INC. $ 39,572,936.00
2
YEAGER SKANSKA INC.
$ 49,976,845.00

The Caltrans District 11 Office is located at 2829 Juan Street, San Diego, CA 92110. The mailing address is P.O. Box 85406, San Diego, CA 92186-5406. The District 11 Duty Senior telephone number is (619) 688-6635. Please submit all inquiries in the proper format by fax to (619) 688-6988 or e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to bidder' inquiries, unless incorporated into a formal addenda to the contract, are not a part of the contract and are provided for the bidder's convenience only. In some instances, the question and answer may represent a summary of the matters discussed rather than a word-for-word recitation. The responses may be considered along with all other information furnished to prospective bidders for the purpose of bidding on the project. The availability or use of information provided in the responses to bidder' inquiries is not to be construed in any way as a waiver of the provisions of Section 2-1.03 of the Standard Specifications or any other provision of the contract, the plans, Standard Specifications or Special Provisions, nor to excuse the contractor from full compliance with those contract requirements. Bidders are cautioned that subsequent responses or contract addenda may affect or vary a response previously given.
Caltrans District 11 Construction Department has developed this method of answering Bidder's Inquiries to better serve the needs of the Contractors who bid on our Projects. Caltrans District 11 Construction Department will post all of the questions submitted by any of the contractors that are registered Planholders for that Contract, but reserves the right to not answer any questions deemed unsatisfactory for public viewing.
The BIDDER'S INQUIRIES & RESPONSES will be updated continuously and all attempts will be made to do the final posting by 15:00 on Wednesday prior to the bid opening.
INFORMATION AVAILABLE
 
 CROSS SECTIONS
BID ITEMS
 SPECIALS
PLANS
 PLANHOLDERS
 ENVIRONMENTAL DOC
 MIBS
 WEB LINKS


ADDENDUM


 


 

BIDDER'S INQUIRY SUBMITTAL FORM
 
 
 
 


 

Inquiry No.
Inquiry
 
 
 
 

1
  Q:02/23/06

  R:02/23/06
Plan Sheet / Specification Reference=

Question=Will you please make the cross-sections available for downloading. 

  • Cross sections are available as of 02/23/06 and can be downloaded for printing from the link above at any local printing firm or on your own printing equipment: 
     MESA BLUEPRINT 
     5560 Ruffin Road Suite 5 
     San Diego, CA 92123 
     (858) 541-1500    FAX (858) 278-0558 
     e-mail to  plot@mesablueprint.com San Diego, CA 92123
2
  Q:03/01/06
  R:03/07/06
Plan Sheet / Specification Reference=Special Provisions: 
Section 10-1.33 Earthwork

Question= 45 day settlement periods are required for the roadway embankments at the Earth Retaining Structures No. 446L/R and 450L/R. 
Is the intent to place the roadway embankment between the future MSE walls, let settle for 45 days, remove embankment and construct MSE walls or to construct MSE walls and roadway embankment between walls and let settle for 45 days prior to begining construction of the approach slab, concrete barrier and barrier slab along the top of the walls. 
The Foundation Recommendation in the Information Handout for walls 446L/R and 450L/R states - "The maximum total embankment settlement under MSE pads is estimated to be 12mm/0.5 inches. While settlement is expected to be instantaneous, and concurrent with fill placement, a settlement waiting period of 30 days should be employed prior to placing any roadway surfacing." 

  • Construct the MSE walls and embankment between the walls and then let settle for 45 days prior to placing the approach and barrier slabs along the top of walls.

 
 
 

3
  Q:03/20/06

R:03/24/06
Plan Sheet / Specification Reference=Bid Item 206 Install Concrete Barrier (movable). Specials Provisions Pages 131 State Furnished Materials, Page 376 10-3.48 State Furnished Movable Barrier.

Question=The Special Provisions state that the movable barrier will be available some where in San Diego County. 
1. Where in San diego County? needed to determin haul time to the job site. 

  • Please refer to Addendum No. 2

  •  
2. What condtion will rail be in? are some 1m segments all ready attached together or all 1m segments seperate. 
  • The rail is stored in three row high stacks. Two barrier segments are pinned together during storage and transport.
3. Is this material new? or is patching and painting required? 
  •  All material is new


4
  Q:03/20/06
    R:03/24/06
Plan Sheet / Specification Reference=Bid Item #85. Asphalt Concrete, Type A. Sheets 246 & 247. 

Question=Detour D-SBCD shown on shets 246 and 247 - Does the detour get construted before or after the final paving during Stage 2? 

  • The detour gets constructed before the final paving, during Stage 2.
 What are the limits and width of the AC pavement detour? 
  • See the hatching on Sheets 246 and ,and the quantity sheets 307 and 310.


 

5
  Q:03/20/06
    R:03/24/06
Plan Sheet / Specification Reference=Bid Items #90 & #91. Concrete Pavement, Doweled/Undoweled.  Multiple sheets, see below.

Question=
1. Sheets 12 & 13 (L-1 & L-2) - Where does the PCCP start?  Plans do not match Conctract 11-080924. 

  • Please bid per the contract documents.
2. Sheets 19 & 20 (L-8 & L-P) - The plan view in the managed lanes does not match the typical sections or the quantity sheets.  What is correct?  Where does the managed lane end? 
  • Plan sheets 20, 307 and 310 all match. The paving ends at Sta 456+20 "SD-15R" Line
3. Sheets 17 & 18 (L-6 & L-7) - From Station 446+19.906 to 451+30.61 at the managed lane, the typical section calls out asphalt paving for the shoulders AC at join, the plans call out grind exiting PCCP and saw cut.  Is this correct? 
  • See sheets 17 and 18 which call out section 8 to be used. Per sheet 2, section 8 is 150 mm AC (Type A). 
4. Sheet 19 (L-8) - From Station 452+43.104 to 453+90 south bound, the typical section does not match the plan view.  Is the PCCP being constructed from 0 meters to 2.5 meters? 
  • See sheet 19. PCCP is being constructed from 3.0 m to 5.0 m.
6
  Q:03/20/06
    R:03/24/06
Plan Sheet / Specification Reference=Bid Item #40.  Cold Plane Asphalt Concrete Pavement.  Sheet 15 (L-4) 

Question=On Ramp VRDSOF, where are the limits of cold plane? 

  • Limits of cold plane area will be from Sta 443+00 to 442+65 "VRPSOF" Line with a width varying from 6.0 m to 7.3 m.
7
  Q:03/20/06
    R:05/12/06
Plan Sheet / Specification Reference=Bid Items #133 to #140.  Storm Drain Pipes. 
 

Question=When will the Contractor be provided plan and profile details for systems 3A, 4, 5, 5A, 6A, 6B, 7, 8, 10, 11, 12, 13, 14, 15, 16, 17? 

  •  Please refer to Addendum No. 2
8
  Q:03/20/06
    R:05/12/06
Plan Sheet / Specification Reference=Bid Item #107.  Minor Concrete, Pipe Encasement.  Sheet 153. 

Question=Quantity for drain system 1Af indidcates 0.9 m3 for 61 meters of 600mm encasement.  Encasement should be approximately 54 m3.  Please verify.

  • Please refer to Addendum No. 2
9
  Q:03/20/06
    R:05/12/06
Plan Sheet / Specification Reference=Bid Item #107.  Minor Concrete, Pipe Encasement.  Sheet 153. 

Question=Drain system 6ff should be approximately 108 m3.  Please verify. 

Drain system 9g - the quantity is listed in the Class 2 concrete column.  The proposed quantities should be approximately 200 m3.  Please verify. 

  • Please refer to Addendum No. 2
10
  Q:03/20/06
    R:05/12/06
Plan Sheet / Specification Reference=Bid Item #104.  Class 2 Concrete, minor structure.  Sheet 153.

Question=Drainage system 3d (1.8 x 1.5 m RCB) - the length does not match the profile.  Which is correct? 

  • Please refer to Addendum No. 2
Drainage system 3o (1.8 m x 1.5 m RCB) - the quantity for the construction of 5.43 meters is not correct.  Please advise. 
  • Please refer to Addendum No. 2
Drainage systems 3e, 3o, 3p, Type A Wingwalls - Detail shown on Sheet 149 does not match this project.  Will correct details be provided? 
  • The Drainage detail sheets  will be delivered as per "SECTION 1 SPECIFICATIONS AND PLANS" of the Special Provisions, pages 15 and 16. 
Drainage systm 6ii - does the quantity of 1.8 m3 belong to 6jj? 
  • Please refer to Addendum No. 2
Drainage system 9g - does the quantity of 42 m3 belong in minor concrete (pipe encasement) column?
  • Please refer to Addendum No. 2
11
  Q:03/20/06
    R:05/12/06
Plan Sheet / Specification Reference=Bid Item #181. Concrete Barrier, 60 Modified. Sheet #64

Question=The detail shown on sheet 64 indicates a 100mm underdrain pipe with permeable material to be installed.  Where does this get paid for?

  • The payment will be made in accordance with Section 4-1.03 CHANGES of the Standard Specifications. 

 
 
 
 

12
  Q:04/12/06

  R:05/09/06
Plan Sheet / Specification Reference=Overhead Sign Structures...Sheet 302 of 640

Question=You have a Bid item and this sheet for (21) new sign structures.  I do not see in the contract documnet plans where they are located.  Did we miss something?
I have now idea where these structures are located, what type pile foundation or type sign they are.  Please clarify.
 

  • As per plan sheet 302 the pile types, pile sizes, sign types, Station line and offset sides are all shown.
           See below for offset distances to center of piles.

          SIGN 2  Sta 439+50,  21.9 m Right of "SD-15R"

         SIGN 4  Sta 446+35,  6.4 m Right of "NCFNOF"
              Sta 446+35,  23.1 m Right of "SD-15L"

         SIGN 9  Sta 452+70,  26.5 m Right of "SD-15R"

         SIGN V1 Sta 325+37,  4.0 & 31.0 m Left of "SD-15R", NB-15

          SIGN V2 Sta 327+35,  4.9 & 33.0 m Left of "SD-15R", NB-15

         SIGN V3 Sta 328+35,  4.2 m Left of "SD-15R", NB-15

         SIGN V4 Sta 337+00,  3.3 & 26.5 m Left of "SD-15R", NB-15

         SIGN V5 Sta 341+95,  2.9 & 26.6 m Left of "SD-15R", NB-15

         SIGN V6 Sta 364+80,  3.3 m Left of "SD-15R", NB-15

         SIGN V7 Sta 408+00,  3.3 m Left of "SD-15L", SB-15

         SIGN V8 Sta 410+90,  3.3 m Left of "SD-15R", NB-15

          SIGN R1 Sta 375+30,  5.7 & 40.0 m Left of "SD-15R", NB-15

          SIGN R2 Sta 397+20,  3.0 & 26.7 m Left of "SD-15R", NB-15

         SIGN R3  Sta 450+78,  5.2 m Right of "NCFNON", NB Off DAR to NB-15
                                       23.4 m Right of "SD-15L", SB 15
 

 


 
 
 
 
 

13
  Q:04/14/06 R:05/12/06

Plan Sheet / Specification Reference=Item #91, Concrete Pavivement undowelled

Question=1. On Sheet 19, L-8.  The paving leader line indicators do not match the cross sections along I-15 Median from Sta 453+00 to 456+20 NB.  No typical sections either.
 

  • Signed Layout and Typical Cross Section sheets will be delivered as per "SECTION 1 SPECIFICATIONS AND PLANS" of the Special Provisions, pages 15 and 16.
2. Section 10-1.25 Portable Changeable Signs, states the we need 12 ea. signs at locations shown.  Where are these locations?  Are the message signs going to run 24/7.  Please Clarify.
  •  Portable Changeable Message Signs will be placed as directed by the Engineer as per The Special Provisions page 203 and per Lane Closure Charts on pages 184 to 199.


3.  There are concrete barrier bid items shown for items not summarized on quantity sheets yet shown on the drawings. Will the quantity sheets be revised to match the bid items and plans.
 

  • Signed Layout and Quantity sheets will be delivered as per "SECTION 1 SPECIFICATIONS AND PLANS" of the Special Provisions, pages 15 and 16.


4. Between Sta 316+00 and 436+00, there are reaches of K-Rail shown to be removed on the quantity sheets but no Layout Drawings have been provided.
 

  • Signed Layout and Quantity sheets will be delivered as per "SECTION 1 SPECIFICATIONS AND PLANS" of the Special Provisions, pages 15 and 16.
5. Sheet 310, Q-7, shows your Concrete Paving Quantity on HOV only up to Station 444+20.  Is this correct or a revised Q-sheet will be released?
 
  • Signed Layout and Typical Cross Sections and Quantity sheets will be delivered as per "SECTION 1 SPECIFICATIONS AND PLANS" of the Special Provisions, pages 15 and 16.

 
 

14
  Q:04/20/06 R:05/12/06

Plan Sheet / Specification Reference=92 - Concrete Pavement (Rapid 
Strength Concrete), Section 10-1.47

Question=1. What is the required thickness of the Rapid Strength Concrete?

  • The Thickness of the Rapid Strength Concrete is per the Loyout sheets and Typical cross section sheets.
2. The second to the last paragraph of Section 10-1.47 describes "the 
contract unit price paid for tie bar....".  Will there be a separate pay 
item for these tie bars or are they incidental to the Rapid Strength 
Concrete pay item?
  • Please refer to Addendum No. 3
            15
   Q:05/01/06
   R:05/08/06
Plan Sheet / Specification Reference= 27 - Maintain Temporary Fence (Type 
ESA) Special Provisions Section 10-1.30

Question=The special provisions state that existing temporary fence (type 
ESA), shown on the plans to be maintained, shall be maintained, and later 
removed....
Where is the existing temporary fence shown on the plans?
Because this is a Lump Sum item, we need to be able to quantify the amount 
of fence to maintain and remove.

  • The ESA fence is shown on L-1, L-2, Q-4.

  •  
     16
   Q:05/03/06
   R:07/08/06 
Plan Sheet / Specification Reference=Bid Item #152 Miscellaneous Iron &
Steel  Drainage System #6m (Drainage Qty. Sht. DQ-3) lists 34 kg. of Misc. I & S

Question=This item is a Concrete Headwall.  What does the 34 kg. consist
of?

  • The 34kg. consists of the reinforcement steel which is included in the concrete item.

  •  

       17
    Q:05/05/06
   R:05/08/06
Plan Sheet / Specification Reference=

Question=There is a statewide AGC Meeting which occurs from May 16 thru 18 in Monterey.  Is it possible to postpone this bid until the following week 5-25-06?
 

  •  The bid opening date can not be postponed.


      18
   Q:05/09/06
   R:05/12/06

 

Plan Sheet / Specification Reference=Response to the answer for Question 
#15. 

Question=I believe the ESA fence shown on L-1, L-2, and Q-4 is the New 
Temporary Fence (Type ESA) called for in bid item #3 (Quantitiy = 535 m). 
The special provisions section 10-1.09 for item #3 state that maintenance 
and removal of this new temporary fence is incidental to bid item #3.
The questions is, where is the Existing Temporary Fence (Type ESA), as 
called for in bid item #27 and described in section 10-1.30, shown on the 
plans?

  • The fence was originally to be placed as part of a change order to Unit 3 contract of the Managed Lanes, but it did not happen. It will be done in accordance with Section 4-1.03 CHANGES of the Standard Specifications, for the Unit 5 Contract.  
 







19

   Q:05/15/06
   R:05/16/06
Plan Sheet / Specification Reference=Bid Item #46 Bridge Removal (Portion), Plan Sheets No. 530 and No. 556.

Question=What are the actual limits of removals of the existing bridge rail per note #6 on Plan Sheet #530 and note #4 on plan sheet #556 

  • 1)  Please refer to the Stationing for Begin and End "Concrete Barrier Type 26R (Mod)," on Plan Sheet 546 of 640, for the limits of removal.

  • 2)  Please refer to the Stationing for Begin and End "Concrete Barrier Type 732R (Mod)," on Plan Sheet 571 of 640, for the limits of removal.


          20
   Q:05/16/06
   R:05/17/06 
 

 

Plan Sheet / Specification Reference= Reinforced Elastomeric Bearing Pads
20mm x 100mm x 300mm and 20mm x 60mm x 150mm
located on sheets 614 and 615 of 640 total sheets.
Special Provision section 10-1.52 Concrete Structures / Elastomeric Bearing
Pads.    

Question=Are the reinforced elastomeric bearing pads located in MSE walls
446 L/R and 450 L/R to be manufactured per Section 51-1.12H of The State of
California Standard Specifications for Construction of Local Streets and
Roads, including the height increase for including shim material?

The only reference given for elastomeric bearing pads in the special
provisions reference back to Section 51-1.12H of the Caltrans Standard
Specifications for Roads and Bridge Construction.

  • The reinforced elastomeric bearing pads in MSE System shall conform to the requirements in Section 10-1.34 "EARTH RETAINING STRUCTURES" of the SPECIAL PROVISIONS.





21

   Q:05/16/06
   R:05/17/06
Plan Sheet / Specification Reference=item 96 grind existing pccp, specials section 10-1.49 grind pccp and plan sheet #309.

Question=The specials state that the grinding of exisiting pccp "shall be performed in the longitudinal direction of the traveled way and shall be done full lane width so that the grinding begins and ends at lines perpendicular to the pavement centerline". The plans have a quantity sheet on page #309 that has a length and M2 which equalls a grind width of 2.13m (7ft). This is an odd width and does not match the directions given in the specials.
  • Please bid per the contract documents.
         22
   Q:05/16/06
   R:05/17/06 
Plan Sheet / Specification Reference=Overhead Signs, Metal Beam Guard Rail Concrete Barrier Type 60 series, various items and special provisions sections

Question=The incomplete, contradictory and ambiguous contract plans and specifications   for  overhead sign, metal beam guard rail, concrete barrier type 60 series  required for this project, render the requirements of Standard Specification Section 2 including the June 19, 2003 amendments provided on page 17 and 18, impossible to comply with. Requirement of the second paragraph of amended 2-1.03 on page 17 is meaningless in the submission of a bid for undefined overhead sign, metal beam guard rail, concrete barrier type 60 series work. Confirm that the second to the last paragraph of Section 1 on page 16 is the definition for bid pricing. Confirm that any contractor's interpretation for pricing is essentially meaningless because the overhead sign, metal beam guard rail, concrete barrier type 60 series work is undefined and lacks completeness accuracy and detail to allow a  contractor to determine requirements of that work. Confirm that until your  design is complete the bid prices are only a guide for determination of rank of bidders. Confirm that you will compensate the contractor for all efforts to assist you in review and preparation of final contract plans and specifications. Confirm that you are prepared to and will provide mutually acceptable contract change order(s) for the final, real contract requirements as the work is defined and before you demand it to be performed. Confirm that you are prepared to and will provide staff to enable preparation of your final contract design and details to assure that Section 4 including incentive/disincentives are not compromised. 

  • Please bid per the contract documents.


23

   Q:05/17/06
   R:05/17/06
Plan Sheet / Specification Reference=Var

Question=Addendum # 3 issued on 5/5/06 revises Section 2 in its entirety. Confirm that Pre-award qualification and Escrow of Bid Documents are no longer a part of this contract requirement.
  • Addendum No. 3 makes no reference to section 2-1.04 Escrow of Bid Documents, of the Special Provisions.