BIDDER'S INQUIRIES & RESPONSES
DISTRICT 11 CONSTRUCTION
CONTRACT NO: 11-241804
ROUTE / KP 11-SD-67-10.7/14.9 
LOCATION In San Diego County Near Lakeside From Willow Road To Vigilante Road..
DESCRIPTION Construct Median Buffer, Concrete Retaining Walls And Widen Shoulders.
ESTIMATE $ 2,030,000
ADVERTISE DATE 04/05/2005
BID OPENING 05/05/2005
FINAL POSTING 05/04/05    @   16:30

BID RESULTS
1
HAZARD CONSTRUCTION CO. $2,021,178.00 
 
2
ERRECA'S INC. $2,465,366.00 
 

The Caltrans District 11 Office is located at 2829 Juan Street, San Diego, CA 92110. The mailing address is P.O. Box 85406, San Diego, CA 92186-5406. The District 11 Duty Senior telephone number is (619) 688-6635. Please submit all inquiries in the proper format by fax to (619) 688-6988 or e-mail to:
Duty_Senior_Const_District11@dot.ca.gov.
The responses to bidder' inquiries, unless incorporated into a formal addenda to the contract, are not a part of the contract and are provided for the bidder's convenience only. In some instances, the question and answer may represent a summary of the matters discussed rather than a word-for-word recitation. The responses may be considered along with all other information furnished to prospective bidders for the purpose of bidding on the project. The availability or use of information provided in the responses to bidder' inquiries is not to be construed in any way as a waiver of the provisions of Section 2-1.03 of the Standard Specifications or any other provision of the contract, the plans, Standard Specifications or Special Provisions, nor to excuse the contractor from full compliance with those contract requirements. Bidders are cautioned that subsequent responses or contract addenda may affect or vary a response previously given.
Caltrans District 11 Construction Department has developed this method of answering Bidder's Inquiries to better serve the needs of the Contractors who bid on our Projects. Caltrans District 11 Construction Department will post all of the questions submitted by any of the contractors that are registered Planholders for that Contract, but reserves the right to not answer any questions deemed unsatisfactory for public viewing.
The BIDDER'S INQUIRIES & RESPONSES will be updated continuously and all attempts will be made to do the final posting by 15:00 on Wednesday prior to the bid opening.
INFORMATION AVAILABLE
  CROSS SECTIONS
BID ITEMS
 SPECIALS
PLANS
 PLANHOLDERS
 AS-BUILT
ADDENDUM

 ADDENDUM NO.1 04/21/05
 
 
 

BIDDER'S INQUIRY SUBMITTAL FORM
 

Inuiry No.
Inquiry

  Q:04/11/05 
  R:04/19/05
 Plan Sheet / Specification Reference=General

Question=Will there be cross-sections available to download, or otherwise?

Cross sections are available as of 04/19/05 and can be downloaded for printing from the link above at any local printing firm or on your own printing equipment: 

     MESA BLUEPRINT 
     5560 Ruffin Road Suite 5 
     San Diego, CA 92123 
     (858) 541-1500    FAX (858) 278-0558 
     e-mail to  plot@mesablueprint.com San Diego, CA 92123

It appears from a field visit that the utility pole at approx station 111+60
(right) is within the structure excavation necessary for the planned
retaining wall.

Above utility pole does not seem to have a conflict with the necessary excavation for the planned retaining wall, given a possible implementation of a temporary retaining system. In accordance to section 10-1.16 "OBSTRUCTIONS" of the Special Provisions, Utility Company Work.  The work described in "Relocation Work" will be performed by the utility company after the associated site preparation work has been competed by the Contractor.  The work listed in "Work to be performed by the Utility Company" is the minimum anticipated work.  The actual work may vary from that listed.

Utility Co. Work Relocation Work
(A) Brace Electrical Power Poles

 


  Q:04/12/05 
  R:04/19/05
Plan Sheet / Specification Reference=

Question=When will cross sections be available?
 

  • Please refer to the response for bidder inquiry 1.
 
3
  Q:04/18/05 
  R:04/19/05
Plan Sheet / Specification Reference=
Question=It appears that a power pole is in conflict with the structure excavation, if not the wall at station 111+60.  Being in Stage 2, are relocation efforts planned currently so it does not impact the project schedule? 
  • Please refer to the response for bidder inquiry 1.
4
  Q:04/19/05 
  R:04/22/05
Plan Sheet / Specification Reference=Item 30, Spec Prov. page 86, 5-1.21

Question= "prior to the migratory bird nesting season of 2/15 through 9/1 veg. mowing......shall be completed..."  This conflicts with other paragraphs allowing work if no birds are present.  Please explain.

Should the contractor discover any evidence of bird nesting, while performing work outside the restricted areas of work, during the nesting season, the contractor shall not disturb the nesting birds or nests, and shall immediately stop work and notify the Engineer. 
 

5
  Q:04/19/05 
  R:04/22/05
Plan Sheet / Specification Reference=Plan Sheet U-1

Question=It appears that shoring will be likely for the R-1 Wall.  Does the state have  additional information re the depth of the sewer line, which looks to be in conflict with the shoring?

AS-BUILT plans are available and can be downloaded for printing from the link above at any local printing firm or on your own printing equipment, and they look best when open in "photo imaging":

     MESA BLUEPRINT 
     5560 Ruffin Road Suite 5 
     San Diego, CA 92123 
     (858) 541-1500    FAX (858) 278-0558 
     e-mail to  plot@mesablueprint.com San Diego, CA 92123
 

6
  Q:05/02/05 
  R:05/02/05
Plan Sheet / Specification Reference

Question=The as build drawings, provided by the web site, for the sewer line
near rw-1 show two 4" force mains, one at 20' right center line and another
at 25'.  This is assuming the center line of 67 shown on the as built and
the contract plans are the same.

This may place the sewer line in the footing of the retaining wall or in the
structural section.  The as builts provided do not show the profile of these
lines.

The utility plan U-1 showes the conflidting sewer line to be a 200mm.  Who
is correct?

  • The two 4" force mains are on oposit side of the centerline of Rte 67. The 8" (200 MM) sewer line is on the same side as the retaining wall. 
7
  Q:05/02/05 
  R:05/03/05
Plan Sheet / Specification Reference=Item #67, Concrete Ditch Lining

Question=There is no bid item for ditch excavation.  The specials are silent
on method of payment for ditch excavation.  The standards state that ditch
excavation will be measured and paid for. What do you want us to do with the cost of the ditch excavation?

  • Please bid per the contract documents, since it's not defined.
8
  Q:05/03/05 
  R:05/03/05
Plan Sheet / Specification Reference=Plan sheet 17 of 148, (C-2) indicates
that the driveway at High Hopes Drive is 200mm PCC.

Question=What bid item is this work paid under?

  • Please bid per the contract documents, since it's not defined. 
9
  Q:05/03/05 
  R:05/03/05
Plan Sheet / Specification Reference=#59 1200 mm RCP DP1-6, DQ1 DQ2
Question=There is no 1200 mm RCP in the plans, please clarify. 
Also on plan sheet C-2, a 200 mm PCC driveway is shown, with no method of pay.  Please clarify.
  • Please bid per the contract documents, since it's not defined.